4. Troubleshooting
► Error Code
S3–3130
► Error message
Scan System Failure: #S3-3130. Call for service
► Symptom
CIS cable in the platen unit is not connected correctly.
► Troubleshooting method
1) Power off the machine.
2) If CIS connection cable is not connected, connect CIS connection cable.
3) If CIS connection cable is connected but this error code has occurred, then disconnect CIS cable. And then,
connect CIS cable again.
4) Power On.
5) If the problem persists, check the cable. If it is defective, replace it.
6) If the problem persists, check the CIS. If it is defective, replace it.
► Error Code
S3–3230
► Error message
Scan System Failure: #S3-3130. Call for service
► Symptom
CIS cable in the ADF unit is not connected correctly.
► Troubleshooting method
1) Power off the machine.
2) If CIS connection cable is not connected, connect CIS connection cable.
3) If CIS connection cable is connected but this error code has occurred, then disconnect CIS cable. And then,
connect CIS cable again.
4) Power On.
5) If the problem persists, check the cable. If it is defective, replace it.
6) If the problem persists, check the CIS. If it is defective, replace it.
4-104