85
Ⅵ. TROUBLESHOOTING
6. Defect related to the POP-UP
Check the condition of
Solenoid
Check the assembling
condition of Strobe PCB and
Strobe FPCB
1. Check the soldering condition of Solenoid
2. Check the assembling condition of Strobe Lock Lever and
Solenoid
There is short-circuit between the Solenoid (-) and Shoe Plate
1. There is short circuit between the Solenoid (-) and Shoe
Plate
2. Check the Strobe Detect SW (Switch error, Short-circuit of
around the SW)
When the camera is turned
on, the flash POP-UP unit is
opened
After pop-up the flash unit,
it can't be closed
Check the assembling
condition of POP-UP spring