OfficeServ 7400 Installation Manual
© SAMSUNG Electronics Co., Ltd.
5-1
CHAPTER 5.
Connecting the Power
This chapter describes how to connect power to the OfficeServ 7400 system.
5.1 Cautions when Connecting Power
When input power is normally supplied, the AC power is supplied to the Power Supply
Unit(PSU), which charges the external battery. If the input power is interrupted, the system
can be operated using the charged power of the external battery.
Cautions to be taken when connecting power to the OfficeServ 7400 system are as follows:
y
AC power of the system supports 110V, 220 V(Free Voltage).
y
Make sure that the input power of the OfficeServ 7400 is within the range of AC
100~240 V and other electric devices, such as motors and compressors, do not use the
same input power.
y
A single AC outlet should be used solely for the system’s AC power. Sharing the AC
power with other devices can cause noise or a voltage drop, resulting in a system
malfunction or fire.
y
Use a stable power source that can always supply AC power since instantaneous
power failures can cause malfunctions or battery failures. Procedure for Connecting
Power.