Deciding on where to install the Air Conditioner (Continue)
MH070FXEA4B / MH080FXEA4B
Indoor unit
Outdoor unit
Power supply
Ø, V, Hz
026/035/052
MH070FXEA4B
MH080FXEA4B
1,220-240, 50
Unit
Outside diameter
Liquid
Gas
026/035
1/4"
3/8"
052
1/4"
1/2"
Piping outside diameter
(h)
(H)
A
B
1 Room max
length
4 Room total max
length
Max height between
indoor unit & outdoor unit
Max height between
indoor units
Dimension
25m
70 m
15m
7.5 m
Composition
A,B,C,D
A+B+C+D
(H)
(h)
Piping length and the height
C
D
Main power switch
600 mm
minimum
300 mm
minimum
300 mm
minimum
600 mm
minimum
CAUTION:
3 m as minimum pipe length: It will
reduce noise and vibration.
This value must be increased at 7.5
meters in case it is connected just one
indoor unit.
System can work with one indoor unit connected, but it is recommended that the TOTAL number
of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
The appearance of the unit may be different from the diagram depending on the model.
Make at least one round:
It will reduce noise and vibration