Level 3 Repair
Distribution, transmission, or infringement of any content or data from this document without Samsung’s written authorization is strictly prohibited.
Confidential and proprietary-the contents in this service guide subject to change without prior notice.
8-53
5. Sensor HUB part
Check the Voltage
C824 or C825 or C822 = 1.8V
Abnormal Sensor HUB part
1. all sensors not working
or 2. gesture/6 axis/magnetic/barometer not working
or 3. RGB / Humidity & Temperature not working
END
No
Yes
Check the Voltage
R818 = 1.8V
No
Yes
Check the X-tal
C823 & C826 = 32.768KHz
No
Yes
Resolder U600 or U805
Resolder U805
Resolder U805 or OSC800
Yes
Sensors working?
Yes
Change U805
No