7. Barometer Sensor
Check the Voltage
C856 = 1.8V
C855 = 1.8V
Abnormal Barometer Sensor part
END
No
Yes
Check the Voltage
R819 = 1.8V
R820 = 1.8V
No
Yes
Barometer Sensor operate
correctly?
No
Yes
Resolder U804 or heat over U600
Resolder U805 or R819 or R820
Replace U805
or
U804 using a Heatgun
Yes