12. Technical data
Installer reference guide / Mono tank integrated type
197
Mono Electrical wiring diagram outdoor unit
• AE050RXYDEG/EU
2. Outdoor Units
AE050RXYDEG/EU
M BLDC
BLDC FAN MOTOR
COMP
COMPRESSOR
OUT-TH
Thermistor OUT(10K)
DIS-TH
Thermistor DISCHARGE(200K)
COND-TH
Thermistor COND(10K)
OLP-TH
Thermistor OLP(200K)
NOTES
1. This wiring diagram applies only to the Outdoor unit.
2. Symbols show as follow :
blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue, grn: green
3. For connection wiring indoor-outdoor transmission F1-F2, indoor-wired remote controller transmission F3-F4.
4.
Protective earth(SCREW)
2-4. Electrical wiring diagram
M BLDC
BLDC FAN MOTOR
OUT-TH
Thermistor OUT(10K)
COND-TH
Thermistor COND(10K)
COMP
COMPRESSOR
DIS-TH
Thermistor DISCHARGE(200K)
OLP-TH
Thermistor OLP(200K)
NOTE
• Symbols show as follow :
BLK: black, RED: red, BLU: blue, WHT: white,
YEL
: yellow, BRN: brown, SKY: skyblue, GRN: green
• Wiring indoor-outdoor communication F1-F2
•
Protective earth (SCREW)