70
Distributor motor defect
Micro switch terminal not connected
Main PBA defect
When micro switch is not detected for over 30
seconds after the Distributor motor starts
PE
Half load
function error
Heater defect
Heater Relay defect
Heater terminal not connected
Main Wire-Harness defect
Main PBA defect
When the temperature change is 39
℉
or less within
the first 10 minutes after the heating starts
HE
Heater
Error
Sub PBA defect
Main PBA defect
When the button is pressed continuously for over 30
seconds
bE2
Button
Error
Low Level Sensor defect – 0.5V when
the switch is closed
Low Level Sensor terminal not
connected
Main PBA defect
When Low Level is detected to cause Error even after
the water supply resumes after Low Level is detected
for the 1
st
time
9E
Low water
level
Error
Thermistor terminal not connected
Thermistor Defect
Main PBA defect
When 0.2V or below, or 4.5V or above is maintained
for over 3 seconds
tE1
Temperature
sensor
Error
Heater Relay defect Normal: ~ 13
Ω
Thermistor defect
Main PBA defect
When the temperature of the Thermistor is 176
℉
or
above for more than 3 seconds
HE1
Expected cause
Occurring condition
Error
Mode
Error type
Error Code List Part 2