Thermistor Temperature / Voltage Chart
8.542
70
158
10.159
65
149
12.140
60
140
14.579
55
131
17.599
50
122
21.385
45
113
26.065
40
104
31.996
35
95
39.517
30
86
49.120
25
77
61.465
20
68
77.454
15
59
98.323
10
50
41
Temp. (ºF)
125.780
5
Resistance (k
Ω
)
Temp. (ºC)
This chart can be used to accurately measure the thermistor resistance according to
the ambient temperature surrounding the device. These measurements must
match this chart with a 5% tolerance for the thermistor to be considered good.
Outside that range the device is defective.