45
6)
After laying the product down and
disassembling the Shutter, separate the Leakage
Sensor terminal assembled on the Shutter.
7)
Separate the terminal of Circulation Motor.
8)
Disassemble the Circulation Motor and
separate it from the Sump assembly.
※
Check List
▶
Be careful of the residual water inside the unit
from prior wash
▶
Check the voltage at the connectors: 120VAC
▶
Check coil resistance: 16.5
Ω
(Measure after
removing connectors)
▶
PCB : Check CN1 -CN14 (120VAC)