4. Troubleshooting
4-16
Error type
Error mode
Checking Method
Corrective actions
The nozzle does not
inject water.
None
1. Check the connections for the Circulation Motor
connector.
- Reconnect the Circulation Motor connector.
2. Check the connections for the Startup Condenser
connector of the Circulation Motor.
- Reconnect the Startup Condenser connector of the Circulation Motor.
3. Check the resistance for the Circulation Motor coil.
(Remove the connector before measuring.)
Normal: Approx. 16.5 Ω
➢
- Faulty: Replace the Circulation Motor.