4. Troubleshooting
4-10
Error type
Error mode
Checking Method
Corrective actions
Thermistor
error
tE1
1. Check the connections for the Thermistor
connector.
- Reconnect the Thermistor connector.
2. Check whether the Thermistor is operating normally.
- Measure the voltage between both ends of the
Thermistor.
Normal: 0.2 to 4.5V
➢
- Measure the resistance between both ends of
the Thermistor:
Remove the connector before measuring.
(See the Table right.)
THERMISTOR TABLE
Temp. (ºC)
Resistance (kΩ)
5
125.780
10
98.323
15
77.454
20
61.465
25
49.120
30
39.517
35
31.996
40
26.065
45
21.358
50
17.599
55
14.579
60
12.140
65
10.159
70
8.542
- Faulty: Replace the Thermistor.