4. Troubleshooting
4-9
Error type
Error mode
Checking Method
Corrective actions
Overflow error
oE
4. Check whether there is any trace of water leakage
on the top of the Case Sensor.
- Clean the Hose-Sensor and the Case Sensor.
5. Check whether an “oE” error is detected when the
assy wire-harness connector for Overflow Sensor is
not connected.
Normal: The “oE” error does not occur.
➢
- Faulty: Replace the Main PBA assy.
- Nomral: Replace the Flow Meter.