4. Troubleshooting
4-13
Error type
Error mode
Checking Method
Corrective actions
Display error
None
2-3. Check the display LED. (the front display of
DMR57)
- Check the number of the part that operates
abnormally. Check the LED on that abnormal
point by inputting 5V to the S part through a
300Ω resistor and grounding the D part.
Nomral: The point lights up normally
➢
Ex) If the D1-a point operates abnormally,
check the connections between pin 1 of the 7-
pin connector and pin 1 of the 6-pin connector.
(See the figure on the right.)
- Faulty: Replace the Display LED.
1
2
3
4
5
6
7
8
D 1
D 2
D 3
9
10
11
a
b
c
d
e
f
g
3. Check the DC voltage of the Main PBA.
- See the “Main PBA DC voltage error”.
Key input part error
None
1. Check Power Key on state.
- Try to turn on the Power Key.
2. Check the connections for the Sub PBA connector
part.
- Reconnect the Sub PBA connectors..
3. Check the DC voltage of the Main PBA.
- See “Main PBA DC voltage error”.