ENGLISH
E-
11
Purging the Unit
On delivery, the indoor unit is loaded with an inert nitrogen gas.
All this gas must therefore be purged before connecting the assembly
piping. To purge the inert gas, proceed as follows.
Unscrew the caps at the end of each pipe.
Result: All inert gas escapes from the indoor unit.
◆
To prevent dirt or foreign objects from getting into the pipes
during installation, do NOT remove the caps completely until
you are ready to connect the piping.
N
N
N
N
o
o
o
o
tt
tt
e
e
e
e
Connecting the Connection Cord
The indoor unit is powered from the outdoor unit via the connection cord.
◆
When connecting the cables, you must pass them through
the cable clamp to fix them securely.
N
N
N
N
o
o
o
o
tt
tt
e
e
e
e
Remove the screw on the electrical component box and remove the cover
plate.
1
Route the connection cord through the side of the indoor unit and connect
the cable to terminals as shown in pages 12 and 15.
2
Route the other end of the cable to the outdoor unit through the ceiling &
the hole on the wall.
3
Reassemble the electrical component box cover, carefully tightening the
screw.
4
Summary of Contents for DH60 T Series
Page 44: ......