H
SI
L
G
N
E
E-
15
DH48FTA 4ge_IM_E<23539 2005.8.16 6:3 PM Page 13
1(L) 2(N) 3(C)
Vc Vc
F1 F2 V1 V2 F3 F4
3(C)
2(N)
1(L)
Receiver &
Display Unit
(Optional)
Float Switch
Drain Pump
(Optional)
Wired
Remote
Controller
MAIN PCB
Power
3
ø
380 - 415V~, 50H
z
MAIN POWER
Indoor Unit
Outdoor Unit
Wiring Diagram (DC48GTVA,DC60GTVA)
Signal
The following electrical characteristics must be respected.
MODEL
Power
Circuit breaker
Indoor unit power cable
Wired remote controller power
& communication cable
Power cable
20m or less
50m or less
DC48GTVA(X),DC60GTVA(X)
3ø 380-415V~, 50Hz
20A
1.25mm
2
(CV, 4 wire)
The power cables are not
supplied with the air
conditioner.
The user should purchase
them separately.
0.5~0.75mm
2
(CV, 2 wire)
2.0mm
2
(CV, 5 wire)
2.5mm
2
(CV, 5 wire)
Note
Cable Specifications
Summary of Contents for DH60 T Series