14
4. Troubleshooting
Weight Sensor
Error
Code
Gas Sensor Error Case (E-1X)
Solution
Page
E-31
Open (When value of HEX is above “FF” for 5 seconds)
Check Sensor.
19 Page
E-32
Short
20 Page
E-33
In case the initial value of HEX is under “14” for 30
seconds while a weight sensor in operation.
23 Page
E-34
In case the initial value of K calculated by a weight
sensor is above and under “±28” as value of HEX.
E-35
In case the value of A is “-” as a weight sensor calculates.
E-36
In case the door opens during sensor cooking.
Cancel the present mode and
restart from the begining.
24 Page
Easy/Ph Sensor
Error
Code Easy/PH Sensor Error Case (E4)
Solution
Page
E-41
Open
Check Sensor.
19 Page
20 Page
E-42
Short
E-43
T1 Max Time Error
21 Page
E-44
Dry Up
Insert food and restart.
21 Page
E-45
Cooling Error (3minutes)
Remove moisture from sensor and restart.
25 Page
E-46
Primary Open Error(3minutes)
Check Sensor.
19 Page
E-47
The door opens during cooking
Cancel the present mode and restart from the
begining.
24 Page
Humidity Sensor
Error Code Humidity Sensor Error Case (E-6X)
Solution
Page
E-61
Open
Check Sensor.
19 Page
E-62
Short
20 Page
E-63
T1 Max Time Error
21 Page
Others
Error Code
Others (E-0X, Letter)
Solution
Page
-SE-
Key Short Error (10 seconds)
Turn off set and restart.
22 Page
E-02
Cooking Time Setting Over Error (MWO)
Check each mode’s setting time.
31 Page
E-03
Cooking Time Setting Over Error (Grill)
E-04
Cooking Time Setting Over Error
(Convection)
E-05
Cooking Time Setting Over Error
(Combination)
E-06
It fails to sense that the swing heater has
stopped for 20 seconds during cooking.
Check Swing heater’s motor and
connector.
34 Page
E-08
In case function of MWO starts with spit
inserted into cavity inside.
Restart after remove spit.
30 Page
E-09
In case the damper is not set to be
positioned for 2 minutes.
Check damper and connector.
32 Page