11
3. Disassembly and Reassembly
3-7 Replacement of Fan Motor
Parts
Explaination Photo
Explaination
Fan Motor
Ventilation Motor
C-Film
Supporter-Fan-Mount
Duct-Fan
1.
Remove the outerpanel and back-cover.
2.
Discharge the high voltage capacitor.
3.
Remove all the lead wires from Magnetron
and High Voltage Capacitor.
4.
Remove 2 screws securing the duct fan.
5.
Remove 2 screws securing the Supporter-
Fan Mount.
6.
Lift the Ventilation Motor Ass’y slightly left
upward and pull it out.
7.
Remove lead wires and connectors.
8.
Remove a screw securing the C-Film to
the Supporter-Fan-Mount.
9.
Turn the fanmotor ass’y over soth at the
bracket side is up.
10.
Remove 2 screws securing the Ventilation
Motor.
3-8 Replacement of Tray
Parts
Explaination Photo
Explaination
Assy
Stirrer
Tray
1.
Open the door.
2.
Remove the tray by inserting a thin metal tool into the gap
between the oven wall and the tray silicon cover.
3.
Insert the new tray by tilting it across the oven cavity.
4.
Firstly
¿
x the front part (refers to the place where the silicon
cover is thinner than the other 3 edges) and then place the
back ward part carefully and
¿
rmly.
NOTE
:
Be careful when you handle the tray since it is fragle.
3-9 Replacement of Lamp
Parts
Explaination Photo
Explaination
Assy
Stirrer
Lamp Holder
Lamp Cover
Outer Panel
NOTE
:
You donn’t need to remove the outer
panel or other parts in order to replace a
lamp
1.
Remove a screw securing the lamp cover.
2.
Remove the lamp by rotating it clockwise.
3.
Replace with a new lamp by rotating it
counter-clockwise
NOTE
:
If it is necessary to replace the lamp
holder, you can disconnect lead wires by
pushing down on the hole of lead wires using
a long pointed tool.
&0$B;(8LQGE
Summary of Contents for CM1529A-1/XEU
Page 3: ...3 1 Precaution 0 B 8 LQGE ...