1) The input voltage should be 198-264VAC.
The air conditioner may not operate properly if the voltage is out of this range.
2) The indoor unit and the outdoor unit shall be linked by 6 cables.
Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables.
Otherwise the air conditioner may not operate pro p e r l y.
3) If a problem occurs as described in the table below, it is a symptom not related to the malfunction of the air
c o n d i t i o n e r.
4 ) Indoor unit observes operation condition of the air conditioner, and displays self diagnosis details
on the display panel.
Samsung Electronics
5-1
5. Troubleshooting
5-1 Items to be checked first
NO
Operation of air conditioner
1
The operation indication LED (Green) blinks when a
power plug of the indoor unit is plugged in for the first time.
2
• In a COOL operation mode, the compressor does not
operate at a room temperature higher than the setting
temperature that the compressor should operate.
• In a HEAT operation mode, the compressor does not
operate at a room temperature lower than the setting
temperature that the compressor and indoor fan should
operate.
3
Fan speed setting is not allowed in AUTO or DRY mode.
4
Compressor stops operation intermittently in DRY mode.
5
Compressor of the outdoor unit is operating although it is
turned off in a HEAT mode.
6
Timer LED only of the indoor unit lights up and the
air conditioner does not operate.
7
The compressor and indoor fan stop intermittently in HEAT
mode.
8
Indoor fan and outdoor fan stop operation intermittently in
a HEAT mode.
9
The compressor stops intermittently in a COOL mode or DRY
mode, and fan speed of the indoor unit decreases.
It indicates power is on. The LED stops blinking if the operation ON/OFF
button on the remote control unit is pushed.
• In happens after a delay of 3 minutes when the compressor is
reoperated. The same phenomenon occurs when a power is on.
• As a phenomenon that the compressor is reoperated after a delay of
3 minutes, the indoor fan is adjusted automatically with reference
to a temperature of the air blew
• The speed of the indoor is changed automatically in DRY mode.
• Fan speed is 4 steps is selected automatically in AUTO mode.
Compressor operation is controlled automatically in DRY mode
depending on the room temperature.
When the unit is turned off while de-ice is activated, the compressor
continues operation for up to 7 minutes (maximum) until the deice is
completed.
Timer is being activated and the unit is in ready mode.
The unit operates normally if the timer operation is cancelled.
The compressor and indoor fan stop intermittently if room temperature
exceeds a setting temperature in order to protect the compressor from
overheated air in a HEAT mode.
The compressor operates in a reverse cycle to remove exterior ice in a
HEAT mode, and indoor fan and outdoor fan do not operate
intermittently for within 20% of the total heater operation
The compressor stops intermittently or the fan speed of the indoor unit
d e c reases to prevent inside/outside air frozen depending on the
inside/outside air temperature.
Explanation
NO
Display
1
OPERATING LED (GREEN) blinking (1Hz)
2
TIMER LED (YELLOW) blinking (5Hz)
3
OPERATING (GREEN), TIMER LED (YELLOW) blinking (5Hz)
4
FAN (GREEN) LED blinking (5Hz)
Restore from power failure (input initial power)
Temperature sensor defective (open, short)
Indoor heat exchanger sensor defective (open, Short)
Indoor fan malfunction (inoperative within 15sec
-less than 600rpm)
Self Diagnosis
Summary of Contents for ASH180UE
Page 2: ...Samsung Electronics Co Ltd APR 1998 Printed in Korea Code No DB81 10154A...
Page 4: ...1 2 Samsung Electronics MEMO...
Page 33: ...Samsung Electronics 5 11 MEMO...
Page 34: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit...
Page 40: ...6 7 Samsung Electronics MEMO...
Page 43: ...Samsung Electronics 7 3 MEMO...
Page 48: ...8 5 Samsung Electronics MEMO...
Page 49: ...Samsung Electronics 9 1 9 Wiring Diagrams 9 1 Indoor Unit...
Page 51: ...Samsung Electronics MEMO...
Page 52: ...Samsung Electronics 10 1 10 Schematic Diagrams 10 1 Indoor Unit...