Selection of installation place
Indoor unit
f
f
Install the unit at a place close to the wall facing the outside as it is necessary to perform piping connection with the
outdoor unit.
- It is effective to install the unit at a window side to ensure uniform distribution of indoor temperature.
f
f
Install the unit at a place where there is no obstacle against the wind around the air intake and air outlet.
f
f
Install the unit horizontally at a stable, rigid place. (When installing the unit at a place subjected to oscillation, noise may
occur.)
f
f
Avoid a place near the door which is frequented by people.
f
f
Avoid a place subject to direct sunlight.
Top view
More than
60cm
[Corner installation]
[Wall installation]
Side view
More than 100cm
More than 50cm
Air outlet
Air intake