Samsung Electronics
5-4
Troubleshooting
5-2-3 When the Outdoor Unit Does Not Operate. (Initial Diagnosis)
1 )
Checklist :
(1) Is input voltage normal?
(2) Is the set temperature of the remote control higher than room temperature in COOL m o d e ?
(3) Is the POWER IN connector (terminal-tab) linked corre c t l y ?
(4) Is the outdoor unit properly connected with the TERMINAL BLOCK connector(5P)?
2 )
Troubleshooting pro c e d u re
(1) Checking pro c e d u res for the indoor unit.
After unplugging out the power cord should be
reconnected within five seconds.
Does the operating lamp blink
YES
YES
NO
NO
NO 1
YES 3
2
NO
YES
1 NO
2 NO
A Room operation
“A”Compreessor or outdoor fan-motor replaced
Power relay is
out of order
Power relay should be
replaced.
PCB should be
checked.
Microcomputer is
out of order.
PCB should be checked.
Room temperature sensor is
out of order
Check as in the procedure "No Power parts"
Refer to page 5-2.
YES 3
Is the room sensor normal register?
10°C
20°C
30°C
17.96k
Ω
12.09k
Ω
8.3k
Ω
Does the timer lamp blink during operation ?
Is the power relay RY71 operated by adjusting the
room temperature?
1) Is AC 198 - 264V applied relay between Terminal Tap(TB71)
and RY 71 terminal No. 3
2) Is AC 198 - 264V applied relay between Terminal Tap(TB71)
andCN 71 terminal No. 1
B Room or C Room operating
Proceed to the checking points for the outdoor unit.
Test rod location
Normal
+
-
Condition
Voltage
IC1 Pin No.63
GND
RY73 ON
DC 4.8V
IC1 Pin No.62
GND
RY72 ON
DC 4.8V
Summary of Contents for AM18A1(B1)E09
Page 2: ...Samsung Electronics Co Ltd DEC 1998 Printed in Korea Code No DB81 10176A 2...
Page 4: ...1 2 Samsung Electronics MEMO...
Page 8: ...2 4 Samsung Electronics MEMO...
Page 24: ...3 16 Samsung Electronics MEMO...
Page 38: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit...
Page 40: ...Samsung Electronics 6 3 6 2 Outdoor Unit 11 10 2 10 3 10 5 10 4 10 1 10...
Page 44: ...6 7 Samsung Electronics MEMO...
Page 46: ...Samsung Electronics 8 1 8 PCB Diagrams 8 1 Main PCB...