Samsung Electronics
3-15
3-3-3(b) AM18A1(B1)E09 / AM18A1(B1)B09 / AM19A1(B1)E07
• Cooling Characteristics - Outdoor Te m p e r a t u re
Test Condition Indoor Unit(DB/WB) : AM18A1(B1)E09/AM19A1(B1)E07 : 27/19, AM18A1(B1)B09 : 27/19.5
Vo l t a g e / F requency : AM18A1(B1)E2/AM19A1(B1)E2 : 240V/50Hz, AM18A1(B1)B2 : 220V/60Hz
10000
Cooling Capacity
Outdoor Temperature(DB/WB)
21/15(15.5)
35/24
43/26(25.5)
Air Outlet Temp.
7000
8000
9000
15
14
13
12
11
10
Cooling Capacity
Low Pressure
10000
Outdoor Temperature(DB/WB)
21/15(15.5)
35/24
43/26(25.5)
7000
8000
9000
7
8
4
3
5
6
Cooling Capacity & Air Outlet Temperature
Cooling Capacity & Low Pressure