![Samsung AC NX S C Series Installation Manual Download Page 2](http://html.mh-extra.com/html/samsung/ac-nx-s-c-series/ac-nx-s-c-series_installation-manual_336654002.webp)
AA
2
English
Safety precautions
Contents
General information
Carefully read the content of this manual before installing the air conditioner and store the manual
in a safe place in order to be able to use it as reference after installation.
For maximum safety, installers should always carefully read the following warnings.
Store the operation and installation manual in a safe location and remember to hand it over to the
new owner if the air conditioner is sold or transferred.
This manual explains how to install an indoor unit with a split system with two SAMSUNG units.
The use of other types of units with different control systems may damage the units and invalidate
the warranty. The manufacturer shall not be responsible for damages arising from the use of non
compliant units.
The manufacturer shall not be responsible for damage originating from unauthorized changes
or the improper connection of electric and requirements set forth in the “Operating limits” table,
included in the manual, shall immediately invalidate the warranty.
The air conditioner should be used only for the applications for which it has been designed: the
indoor unit is not suitable to be installed in areas used for laundry.
Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the
power supply.
In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection
switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is
hot or damaged or if the unit is very noisy.
Always remember to inspect the unit, electric connections, refrigerant tubes and protections
regularly. These operations should be performed by qualified personnel only.
The unit contains moving parts, which should always be kept out of the reach of children.
Carefully follow the precautions listed below because they are essential to guarantee the safety
of the equipment.
• Always disconnect the air conditioner from the power supply before
servicing it or accessing its internal components.
• Verify that installation and testing operations are performed by qualified
personnel.
• Verify that the air conditioner is not installed in an easily accessible area.
WARNING
Safety precautions ................................................................................................................................................................... 2
Preparation for outdoor unit installation ........................................................................................................................... 4
Deciding on where to install the outdoor unit ................................................................................................................ 6
Outdoor unit installation .................................................................................................................................................... 10
Connecting the cable ........................................................................................................................................................... 12
Extending the power cable ................................................................................................................................................. 18
Connecting the refrigerant pipe ....................................................................................................................................... 20
Connecting up and removing air in the circuit .............................................................................................................. 21
Cutting/Flaring the pipes .................................................................................................................................................... 22
Performing leak tests ......................................................................................................................................................... 23
Insulation ............................................................................................................................................................................... 24
Using stop valve ................................................................................................................................................................... 25
Adding refrigerant ............................................................................................................................................................... 26
Pump down Procedure ........................................................................................................................................................ 27
Checking correct grounding ............................................................................................................................................. 28
Testing Operations ................................................................................................................................................................ 29
Troubleshooting ................................................................................................................................................................... 31