EB 5857 EN
9-1
Malfunctions
9
Malfunctions
Î
Troubleshooting (see Table 9-1).
Contact SAMSON's After-sales Service for malfunctions not listed in the table.
Table 9-1:
Troubleshooting
Error
Possible reasons
Recommended action
Actuator stem does not move.
Actuator is blocked.
Î
Check attachment.
Î
Remove the blockage.
No or incorrect supply voltage
connected.
Î
Check the supply voltage
and connections.
Actuator stem does not move
through the whole range.
No or incorrect supply voltage
connected.
Î
Check the supply voltage
and connections.
The actuator does not control the
valve position
1)
.
The actuator was not initialized
during start-up.
Î
Check the switch position
of the direction of action
switch.
Î
Initializing the actuator
The mounting has been changed.
1)
Version with positioner only
9.1
Error indication by LEDs (version with positioner)
Blinking pattern of the red LED
−
Limit contact error
On
Off
Time in s
−
Input signal failure detected
On
Off
Time in s
Note
Summary of Contents for 5857
Page 6: ......
Page 12: ...1 6 EB 5857 EN...
Page 20: ...3 6 EB 5857 EN...
Page 44: ...8 12 EB 5857 EN Operation...
Page 48: ...10 2 EB 5857 EN...
Page 50: ...11 2 EB 5857 EN...
Page 52: ...12 2 EB 5857 EN...
Page 54: ...13 2 EB 5857 EN...
Page 56: ...14 2 EB 5857 EN...
Page 58: ...15 2 EB 5857 EN Certificates EU declaration of conformity...
Page 59: ...EB 5857 EN 15 3 Certificates TR CU certificate...
Page 60: ...15 4 EB 5857 EN Certificates...
Page 72: ...16 12 EB 5857 EN...
Page 76: ...17 4 EB 5857 EN...
Page 77: ......
Page 78: ......
Page 79: ......