EB 8072 EN
5-5
Installation
Risk of valve damage due to the use of
unsuitable tools.
Î
Only use tools approved by SAMSON
(
u
5.3.1 Mounting the external
anti-rotation fixture
Before mounting the actuator, the external
anti-rotation fixture must be mounted onto
the plug stem in some cases. The valve must
be closed beforehand.
For SAMSON Type 3271 and Type 3277
Actuators with Type 3273 Hand-operated
Actuator, observe the mounting and operat-
ing instructions of the hand-operated actua-
tor (handwheel) to mount the anti-rotation
fixture
u
a) Standard version for
Series 290 Valves, NPS 6
and larger
1.
Insert ball bearings (310) into the recess-
es in the bonnet.
2.
Place the yoke (3) on the bonnet in such
a way that the ball bearings fit into the
recesses of the yoke.
3. Fasten the yoke (3) using the castellated
nut (92).
4.
Fasten the hanger (83) and warning la-
bel (255), if applicable, to the yoke us-
ing the screws (82).
NOTICE
!
3
83
82
82
310
310
92
84
85
255
Legend
3
Yoke
82
Screws
83
Hanger
84
Travel indicator scale
85
Screws
92
Castellated nut
255
Warning label
310 Ball bearing
Plug stem
Fig. 5-1:
Overview of yoke assembly with travel indicator scale in the standard version
Table 5-4:
Tightening torques
Screw size
Tightening torque
[Nm]
M12
50
M16
121
13. Check and ensure the following:
− There is a nominal clearance of 0.5
to 1 mm between the sliding washers
and their contact surface on the yoke
on each side (see detailed view Y in
− The anti-rotation fixture does not get
stuck on the yoke and can move free
-
ly in the direction of travel.
14.
Extend the actuator stem again and
mount the stem connector clamps.
Summary of Contents for 3291
Page 14: ...1 10 EB 8072 EN...
Page 30: ...4 6 EB 8072 EN Shipment and on site transport...
Page 56: ...8 4 EB 8072 EN...
Page 82: ...12 2 EB 8072 EN...
Page 84: ...13 2 EB 8072 EN...
Page 86: ...14 2 EB 8072 EN...
Page 87: ...EB 8072 EN 14 3...
Page 88: ...14 4 EB 8072 EN...
Page 91: ...EB 8072 EN 15 3 Annex...
Page 95: ......