TROUBLE SHOOTING FLOW CHART VER1.0
4-
5
3. ONE HORIZONTAL LINE RASTER (NO VERTICAL SCAN)
4. ONE VERTICAL LINE RASTER (NO HORIZONTAL SCAN)
5. ABNORMAL CORNER FOCUS (ABNORMAL DYNAMIC FOCUS)
Check/replace IC501
Check/replace
IC001
Check VERT. YOKE
connector
Check +19V voltage
Check/replace IC691,
Q6C4, D6C1, D6C2
Check D759,
C766,L757
Check/replace T6C1
Normal
Abnormal
Check/replace IC691
Check/replace Q665, D664, Q604
Check DY connector
Check IC661, IC631, IC632
Check +12V voltage
Normal
Abnormal
Normal
Abnormal
Abnormal Normal