FACTORY & ELECTRONIC ADJUSTMENT VER 1.0
3
-2
PURITY ADJUSTMENT
NOTE: Before attempting any PURITY ADJUSTMENTS, the receiver should be operated for at least
30 minutes at White Rasher.
1.
Demagnetize the picture tube and cabinet using a degaussing coil. (East direction)
2.
Slowly move the DY forward or backward with moving 2 pole magnet of CPM until Green beam
registration rank “a” is become
Tighten the clamp screw of the DY with correct rasher-rotation.
■
DISTORTION (VERTICAL) BALANCE ADJUSTMENT
Tilt front of DY up or down to obtain best balance of Top and Bottom distortion.
■
CONVERGENCE ADJUSTMENT
NOTE: Before attempting any convergence adjustment the receiver should be operated for at least 15
minutes.
1.Pan front of DY right or left to obtain better convergence of Yv (R or B wide pattern), and put
d
d
d
d
WEDGE into right and left space with temporary Mounting WEDGE.
B
B
R
R
Registration Rank
Rasher-rotation
a
a
60mm
+0.74
1 dot
Face to south
-0.74
1 dot