moDeL no.
Sam-1500c-12
output: inverter moDe
CoNTINUoUS ACTIVe oUTPUT PoWer
1500W (Power Factor = 1)
MAXIMUM SUrGe PoWer
3000W (<4 millisec; Power Factor = 1)
NoMINAL oUTPUT VoLTAGe
115 VAC, +10% / -5%
OUTPUT FREQUENCY
60 Hz ± 5%
EFFICIENCY
87% (@ 100% load)
INVerTer oN/off CoNTroL
by front panel Switch
output: GriD paSS tHrouGH
NOMINAL VOLTAGE, FREQUENCY OF GRID
120 VAC, 60 Hz
MAXIMUM PoWer
1500W (Power Factor = 1; Battery fully charged)
input: Battery
BATTERY SYSTEM VOLTAGE
12V (10.5V to 15.5V ± 0.5V)
DC CURRENT DRAW FROM BATTERY AT
1500W oUTPUT PoWer
150ADC at battery voltage of 12.5 VDC
DC No LoAD CUrreNT DrAW IN INVerTer MoDe
0.65A to 0.85A
input: GriD
NOMINAL VOLTAGE, FREQUENCY
120 VAC, 60 Hz
MAXIMUM AC INPUT CUrreNT
15A (Protected by 15A breaker supplying Grid input)
tranSfer reLay K1
CURRENT RATING OF TRANSFER RELAY
30A
TrANSfer TIMe froM GrID To INVerTer
2 to 3 seconds
TrANSfer TIMe froM INVerTer To GrID
Up to 1 second
GrounD SWitcHinG reLay K2
CUrreNT rATING
12A
Battery cHarGer
CHArGING ALGorITHM
2 Stage Charger - bulk & float
fLoAT VoLTAGe
13.8V ± 0.3V
bULK CHArGe/MAX. CHArGING CUrreNT
15A
MAXIMUM AC INPUT CUrreNT
< 5A at 120 VAC
AC INPUT PoWer fACTor
0.6
EFFICIENCY
80 ± 5%
VoLTAGe & CUrreNT rATING of fUSe
5 mm x 20 mm, Fast Acting Glass Tube Fuse
125V / 250V, 5A ; Bussman GMA-5 or equivalent
CHArGer oN/off CoNTroL
by front panel Switch
paSS tHrouGH moDe: LoaD SiDe
oVerLoAD / SHorT CIrCUIT SHUTDoWN
Load >15A: Input Circuit breaker on the unit will trip
paSS tHrouGH moDe: cHarGer Section
HIGH AC INPUT VoLTAGe SHUTDoWN
143 VAC. Auto reset at 138 VAC (No transfer to Inverter)
LoW AC INPUT VoLTAGe SHUTDoWN
< 10 VAC. Auto reset at > 75 VAC (No transfer to Inverter)
protectionS: inverter moDe
oVerLoAD SHUTDoWN
> 1650 ± 10% for up to 7 sec
LOW BATTERY INPUT VOLTAGE ALARM
10.8 ± 0.3V
LOW BATTERY INPUT VOLTAGE SHUTDOWN
10.5 ± 0.3V ; Auto reset at 11.7 ± 0.3V
BATTERY (INPUT) OVER VOLTAGE SHUTDOWN
> 15.5V ; Auto reset at < 15.5V
CooLING - LoAD CoNTroLLeD fAN
Inverter Mode: ON at 85W ; Charging Mode: ON at charging
current > 3A ± 1A
INVerTer oVer TeMPerATUre SHUTDoWN
Internal hot spot > 88
o
to 110
o
. Auto reset when hot spot
cools down 10
o
to 15
o
C below the threshold
GroUND fAULT SHUTDoWN IN INVerTer MoDe
Leakage > 5.8 mA. Manual reset
GroUND fAULT SHUTDoWN IN
CHArGer / PASS THroUGH MoDe)
GfCI of AC outlet supplying AC input will trip
DC INPUT REVERSE POLARITY
Fuse 240A (8 pcs. 30A Automotive Type ATC Fuses in parallel)
connectionS
DC INPUT
Nut & bolt, M9
AC INPUT / AC oUTPUT
6 foot cord with NEMA5-15P Plug / 2 x NEMA5-15R Outlets
GeneraL
LED DISPLAY
GREEN “Inverter”; GREEN “Charger”; RED “Fault”; YELLOW
“Input fault”
OPERATING TEMPERATURE RANGE (MIN. TO MAX.)
0°C to 25°C / 32°F to 77°F at 100% loading ; 26°C to 35°C / 78.8°F
to 95°F at 80% loading
OPERATING HUMIDITY < 80%; Non-condensing
DIMENSIONS (W X D X H) 202 x 345 x 84 mm / 7.95 x 13.58 x 3.30 in
WeIGHT
4.0 kg / 8.82 lb