4 | SAMLEX AMERICA INC.
•
If you need to remove a battery, always remove the Ground (Nega
-
tive) terminal from the battery first. Make sure that all the accesso-
ries are off so that you do not cause a spark.
4. Do not make any electrical connections or disconnections in areas desig-
nated as
iGnition protecteD.
This includes 12VDC Power Plug (Cigarette
Plug) connections and terminal connections.
5. This is not a toy - keep away from children.
6. Do NoT insert objects into the ventilation air vents.
!
caution!
1. Please ensure that the Grid AC Power input is fed from 15A/20A GfCI
protected outlet to provide Ground fault Protection when the unit is oper-
ating in Charger / Grid AC Pass Through Mode
2. Connect the external Chassis Ground Connection (15, Fig 3.1) to Earth
Ground using at least AWG #8 wire.
3. When Inverter is supplying AC loads, the voltage on the Neutral and Line
Socket of the NeMA5-15r AC outlet with respect to the Ground Socket /
metal chassis of the unit / metal chassis of the AC loads will be a pulsing
DC voltage with average DC value of up to 50V (will falsely read 75 VAC
on AC scale of the Voltmeter because of pulsing nature of DC voltage).
Do
not toucH tHe neutraL SocKet / neutraL conDuctorS of tHe ac
outLetS!
4. Do not connect AC output from NeMA5-15r outlets to AC distribution wir-
ing where the Neutral is bonded to earth Ground. The inverter will see this
as abnormal condition of Ground fault and will shut down.
5. Do not use with Positive Grounded Electrical Systems (the majority of mod
-
ern automobiles, rVs, trucks and boats use Negative Grounded electrical
Systems).
6. observe correct polarity when connecting the DC input terminals of the
inverter to the battery. Connect Positive of the battery to the Positive input
connector of the Inverter and the Negative of the battery to the Negative
input terminal of the Inverter.
reverse polarity connection will result in a
blown fuse and may cause permanent damage to the inverter. Damage
due to reverse polarity is not covered under warranty.
7. This Inverter will not operate high wattage appliances that exceed the
output power limit or the surge power limit.
8. Do not operate this Inverter if it is wet.
9. Do not install in engine compartment – please install in a well-ventilated area.
10. This Inverter is not tested for use with medical devices.
SeCTIOn 1 |
Safety Instructions
Summary of Contents for SAM Series