JOLLY
www.larius.com
13
REV.
01 - 09/2020 - Cod. 150165
Recirculating-safety valve: when working at the
maximum pressure available, releasing the gun
trigger can cause sudden increases of pressure.
In this case, the recirculating-safety valve opens
automatically discharging part of the product from
the recirculating tube.
Then it closes so as to go back to the previous
working conditions.
Never point the spray gun towards yourselves or
other people. The contact with the casting can
cause serious injuries.
In case of injuries caused by the gun casting, seek
immediate medical advice specifying the type of
the product injected.
For all alarms, the machine shuts down and signals
the type of abnormality by means of a series of
flashes.
As for alarm No. 6, light signalling through a se-
ries of uninterrupted flashes is provided without
machine shut-down. The operator must, however,
immediately connect the unit to an adequate
grounding system.
LARIUS assumes no responsibility for failure to
comply with this requirement.
•
Close the recirculating-safety valve (
I2
)
(turn clockwise to
release the valve)
.
• The machine will continue to suck the product till the flexible
hose is full up to the set pressure.
Then it will automatically stop.
•
Adjust the operation pressure with the knob
(
I3
).
SPRAY ADJUSTMENT
•
Slowly turn clockwise the pressure control knob to reach the
pressure value in order to ensure a good atomization of the
product.
•
An irregular and marked spray on the sides indicates a low
working pressure. On the contrary, a too high pressure
causes a high fog
(“overspray”)
and waste of product.
•
In order to avoid overthickness of paint, let the gun advance
sideways
(right-left)
when spraying.
•
Always paint with regular parallel bands coats.
•
Keep a safety and constant distance between the gun and
the support to be painted and also keep yourselves perpen-
dicular to it.
PROCEDURE TO UNLOCK THE SUCTION GROUP BALL
Should the ball of the suction group be blocked, the unit does
not suck the product anymore.
Procedere to manually release the ball as follows:
• Press several times the suitable device (
I5
).
PRESS
ALARMS
• Flashing lamp (
I6
) for alarms:
Fig. 7I
I2
I5
Fig. 8I
Fig. 9I
I6