background image

www.larius.com

23

GHIBLI 10:1

ED.

 05 - 10/2020 - Cod. 150154

We           Larius S.r.l.
 

Via Stoppani, 21

 

23801 Calolziocorte (LC)

declare under our sole responsability that the product:

GHIBLI series pneumatic piston transfer pump.

to  which  this  declaration  relates  complies  with  the  following 
directives:

 

- Directive 94/9/EC    (ATEX) 

The conformity are under observance of the following standards 

3

X

or standards documents:

 

- EN 1127-1            - EN 13463-5

 

- EN 13463-1

Markings

  

 

         II  2 G   c  IIB  T6      Tamb.: - 20°C  ÷  60°C      Tmax. fluid: 60°C

Tech. File:

 GHIBLI/ATX/08 

Technical dossier kept on file c/o:

 INERIS (0080)     

Calolziocorte- LC, 15/12/2008

                              

Signature (LARIUS)

EXAMPLE OF INSTALLATION

The diagram shows a typical example of the installation of series 
pneumatic piston transfer pump 

DECLARATION
OF CONFORMITY

Summary of Contents for Larius GHIBLI 10:1

Page 1: ...II 2 G c IIB T6 w w w l a r i u s c o m ED 05 10 2020 Manuale Cod 150154 OPERATING AND MAINTENANCE MANUAL EN GHIBLI 10 1 Piston pneumatic transfer pumps...

Page 2: ...manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconv...

Page 3: ...K L O P Q R S T U V W WARNING 2 DESCRIPTION OF THE EQUIPMENT 3 TECHNICAL DATA 4 tRANSPORT AND UNPACKING 5 SAFETY RULES 5 CONDITIONS OF GUARANTEE 6 EXAMPLES OF USE 6 SETTING UP 7 OPERATION 7 CLEANING...

Page 4: ...nt carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not...

Page 5: ...ansferring of fluids Ghibli pump is essentially constitutedofanairmotorandastructurecalled materialpumping group or simply pumping group In the pneumatic motor the compressed air causes the vertical r...

Page 6: ...LESS STEEL AISI 303 AISI 304 AISI 420B Sealing balls STAINLESS STEEL AISI 420B Gaskets PTFE Viton OTHER PARTS OF THE PUMP Motor casing and motor piston ALUMINIUM GHIBLI 10 1 Maximum working pressure 7...

Page 7: ...ABOUT THE USE OF SAFETY DEVICES FOR THEIR OWN SAFETY AND ABOUTTHEGENERALRULESFORACCIDENTPREVENTION INCOMPLIANCEWITHINTERNATIONALREGULATIONSAND WITH THE LAWS OF THE COUNTRY WHERE THE PLANT IS USED THE...

Page 8: ...ce of potentially explosive gas Always check that the product is compatible with the materials composing the equipment pump spray gun flexible hose and accessories with which it can come into contact...

Page 9: ...king again every time the trigger of the spray gun is pressed or the delivery valve is opened Check that the packing nut is not loosened causing the co mingoutoftheproduct Totightenthepackingnutfollow...

Page 10: ...so as to avoid the seizure of the pumping piston and the eccesive wear of sealing gaskets In case of persistent coming out of product provide for the replacement of the upper sealing gaskets see on pa...

Page 11: ...r see on page 10 Crosspiece screws failure of the pneu matic motor Replace the screws see on page 10 Acceleratedworkingandnopressure of the pump Lack of product Add product The pumps sucks air Checkth...

Page 12: ...uld allow the recovery of the valves In case the motor is blocked proceed as follows Unscrew the eyebolt or handle plug M1 and pull it upwards together with the guide rod M2 so allowing the manual rel...

Page 13: ...ballhousingandballarenotruined thencleanand orreplace the parts Insert again the ball and the stop ball pin Adjust the ball stroke according to the type of product being used For thick products the ma...

Page 14: ...screw the fitting P3 Exctract the necessary lower gaskets P4 supplied as spare parts For the reassembling of the gaskets respect the order as shown in the drawing REPLACEMENT OF THE UPPER GASKETS Unsc...

Page 15: ...od from the housing Unscrewthepackingnut Q4 useametalrodwithaninternal diameter of 6 mm Remove the gaskets and packing glands Forthecorrectreassemblingofthegasketsseetheillustration below and the expl...

Page 16: ...020 Cod 150154 1A 1 2 3 4 5 6 7 14 15 16 19 35 36 37 38 24 25 26 29 27 28 32 34 33 18 17 9 10 11 13 12 11 10 8 20 21 22 23 9 39 31 39 30 COMPLETE PNEUMATIC MOTOR REF 96669 WARNING always indicate code...

Page 17: ...pin 2 8 96008 Rocker 1 9 4108 Nut M8 4 10 32024 Washer 2 11 96111 Gasket 4 12 96112 Bush 2 13 96110 Traverse 1 14 96012 O Ring 1 15 96010 Guiding rod 1 16 96009 Rubber valve 2 17 96025 Screw M4 2 18 9...

Page 18: ...9 10 11 12 13 14 15 16 19 20 21 22 23 24 25 23 20 21 26 17 18 18 3 1 2 32 COMPLETE PUMPING GROUP GHIBLI 10 1 PUMP SPLIT Code Description 96674 Long pumping group 96676 Medium pumping group 96675 Short...

Page 19: ...tie rod 1 Pos Code Description Q ty 18 81010 Nut M12 2 19 91334 Bush 1 20 95021 Ball 7 8 1 21 98006 Washer 2 22 91336 Combspring forleathergasket 2 23 91384 PTFE gasket standard 2 91337 Leather gaske...

Page 20: ...10 11 12 13 14 15 16 19 20 21 23 24 25 23 21 26 17 18 18 1 2 22 3 COMPLETE PUMPING GROUP GHIBLI 10 1 PUMP SPLIT ST STEEL Code Description 98050 Long pumping group 98052 Medium pumping group 98051 Shor...

Page 21: ...luid cylinder 1 98021 Short fluid cylinder 1 17 98060 Long tie rod 1 98062 Medium tie rod 1 98061 Short tie rod 1 Pos Code Description Q ty 18 3806 Nut M12 2 19 98005 Bush 1 20 95021 Ball 7 8 1 21 980...

Page 22: ...drums 510090 double post ram for max lt 60 drums Code Description 96038 Wall mounting bracket 16608 Suction hose thick products filter 16612 St Steel suct Hose thick products filter 91107 Air pressur...

Page 23: ...Valve ball GC 1 21 bar 45 l min 96701 96755 3 1 3 7 bar GC 1 2 Valve ball GC 1 21 bar 45 l min 96705 96715 3 1 3 7 bar GC 1 2 Valve ball GC 1 21 bar 45 l min 96660 96661 10 1 3 7 bar GC 1 2 Valve bal...

Page 24: ...y solid materials from entering the pump The air used to power the pump must be filtered and must come from a SAFE AREA II Group II surfaces 2 Category 2 zone 1 G Explosive atmosphere containing gasse...

Page 25: ...irectives Directive 94 9 EC ATEX The conformity are under observance of the following standards 3 X or standards documents EN 1127 1 EN 13463 5 EN 13463 1 Markings II 2 G c IIB T6 Tamb 20 C 60 C Tmax...

Page 26: ...I n t e n t i o n a l l y b l a n k p a g e...

Page 27: ...e LVD furthermore to the harmonized standards UNI EN ISO 12100 1 2 Machinery safety basic concepts general principles of design Basic terminology methodology Technical principles This declaration rela...

Page 28: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...

Reviews: