EN 

 

     EU CONFORMITY DECLARATION

 

I undersigned Rudy Bigand, Technical Director of the company Sammode  SA, located at 24 rue  des  Amandiers 75020 
PARIS, declares that following products (group IIC category 3G  and group IIIC category 2D) : 
 
-

 

LFSn 118, DAVY 1x18

 - 1 lamp T8 18 W G13 / Classe 1 ou 2 / 230 Volts / 50/60Hz 

-

 

LFSn 136, DAVY 1x36 - 

1 lamp T8 36 W G13 / Classe 1 ou 2 / 230 Volts / 50/60Hz

 

-

 

LFSn 158, DAVY 1x58 - 

1 lamp T8 58 W G13 / Classe 1 ou 2 / 230 Volts / 50/60Hz

 

-

 

LFSn 218, DAVY 2x18 - 

2 lamps T8 18 W G13 / Classe 1 ou 2 / 230 Volts / 50/60Hz

 

-

 

LFSn 236, DAVY 2x36 

- 2 lames T8 36 W G13 / Classe 1 ou 2 / 230 Volts / 50/60Hz

 

-

 

LFSn 258, DAVY 2x58 

- 2 lamps T8 58 W G13 / Classe 1 ou 2 / 230 Volts / 50/60Hz

 

 
meet the following regulatory requirements: 

 
ElectroMagnetic compatibility Directive (EMC) 2014/30/EU 

 

To ensure compliance the product meets specific standards lighting fixtures: EN 55015 relating to radio disturbance 
and EN 61547 on immunity. Moreover, the active components are themselves in conformity with the EMC Directive 

 
Low Voltage Directive (LVD) 2014/35/EU 

To  ensure  compliance  the  product  meets  the  standards  of  fixtures  series  EN  60598,  the  active  components  are 
themselves consistent with the LVD. 
All equipment leaving the assembly shall be test operation and safety, especially dielectric and earthing continuity. 

 

 

Environmental Directives 

Directives  2011/65/EU  (on  the  restrictions  on  the  use  of  certain  hazardous  substances  in  Electrical  and  Electronic 
Equipment) Directive 2012/19/EU and (Known as WEEE, Waste Electrical and Electronic Equipment). 

 
 

ATEX Directive 2014/34/EU

 

To ensure compliance the product meets the followings standards: 

-

 

EN 60079-0:2012/A11 :2013 (Explosive Atmospheres - Equipment – General requirements),  

-

 

EN  60079-15 :2010  (Electrical  apparatus  for  explosive  gas  atmospheres  –  Part  15:  Construction,  test  and 
marking of type of protection "n" electrical apparatus) 

-

 

EN 60079-31 : 2014 (Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t") 

-

 

The EC-type examination certificates INERIS 03 ATEX 0011X et INERIS 03 ATEX 3004X delivered by the notified 
body  INERIS, 0080, F-60 550 Verneuil-en-Halatte. 

 
 
 

 

 

 

 

 

 

 

Paris 5 January 2017 

 

 

 

 

 

 

 

 

RUDY BIGAND  

  

 

 

 

 

 

 

 

Technical Director 

 
 
 
 
 
 
 
The notified body involved in the production control stage, or the product itself is : INERIS, n° 0080, F-60550 Verneuil-
en-Halatte.

 

 

Summary of Contents for DAVY LFSn

Page 1: ...mode SA Notice DAVY r v E 24 rue des Amandiers F 75020 Paris 1 12 Janvier 2017 DAVY LFSn Notice d instructions User s guide Gebrauchsanweisungen II 3G Ex nA IIC T4 Gc II 2D Ex tb IIIC T80 C Db IP66 IP...

Page 2: ...UCTIONS NE PAS OUVRIR SOUS TENSION NE PAS OUVRIR SI UNE ATMOSPHERE EXPLOSIVE EST PRESENTE POTENTIAL ELECTROSTATIC CHARGING HAZARD SEE INSTRUCTIONS DO NOT OPEN WHEN ENERGIZED DO NOT OPEN IN CASE OF POT...

Page 3: ...former occasionnellement en service normal zone 2 R gion dans laquelle il n est pas probable qu une atmosph re explosive gazeuse apparaisse en fonctionnement normal et o si elle appara t il est proba...

Page 4: ...e en toute situation il faudra se conformer aux documents d installation concern s NF C 15 100 Maintenance R alis e par du personnel comp tant et habilit L exploitant l utilisateur doit s assurer que...

Page 5: ...antir sa conformit le produit r pond aux normes luminaires de la s rie EN 60598 les composants actifs tant eux m mes conformes la DBT Tous les appareils sortant de montage font l objet d essais de fon...

Page 6: ...air is not liable to gather under normal operating conditions and where should it occur it would not be in a frequent way and it would occur for a short while only Determination and delimitation of th...

Page 7: ...the relevant installation documents shall be complied with Maintenance To be carried out by trained and duly approved staff The user should make sure that the conditions of use and maintenance are com...

Page 8: ...e Directive LVD 2014 35 EU To ensure compliance the product meets the standards of fixtures series EN 60598 the active components are themselves consistent with the LVD All equipment leaving the assem...

Page 9: ...malen Bedingungen nicht ergeben sollte und an dem sollte es der Fall sein w rde es nicht fters auftauchen und dann auch nur f r eine vor bergehende Zeitspanne F r die Bestimmung und Festlegung dieser...

Page 10: ...uf jeden Fall den jeweiligen Unterlagen gem ss getroffen werden Wartung Sollte nur durch trainiertes Personal ausgef hrt warden Der Benutzer sollte sichern dass die Gebrauchs und Wartungsbedingungen b...

Page 11: ...spannungsrichtlinie 2014 35 EU Zur Gew hrleistung der Konformit t entspricht das Produkt den Leuchtennormen der Serie EN 60 598 wobei die aktiven Bauelemente der Niederspannungsrichtlinie entsprechen...

Page 12: ...cations for the marking of the equipment English labels are provided with the luminaire Stick them on the French version Angaben f r die Markierung der Leuchte Die deutschen Etiketten werden mit den L...

Reviews: