2 Connection (To be carried out when voltage is off )
2.1
Strip the power supply cable on 35 to 70 mm (depending on whether it is flexible or rigid), then strip each
conductor on 7 mm.
2.2
Insert the power supply cable through the cable gland of the mobile flange
without tightening it.
2.3
Connect both live and neutral connectors to the relevant terminals of the block (~ and ~ or L and N).
2.4
Connect to the earth the screw
(marked
) on mobile flange
.
Important:
-
The mains supply of the device must be taken downstream from the protection device and upstream from the
control device for the normal lighting of the room where it is installed.
-
To ensure the required tightness, use a round supply cable, for example a U1000 R2V or H 07 RNF 3G1.5² in those
cases (the contractor is responsible for the choice of the cable).
Note:
-
As the cable gland supplied with the luminaire is certified ‘Ex e’, ‘Ex d’,
II 2 D or
II 2 G (with IP64
minimum), it is strictly forbidden to replace it with another one.
-
In order to provide the tightness required, the cable gland used is designed for one and only one round cable with
an external diameter included between 10 and 12 mm. For the choice of the cable (type and nominal section), in
any situation, the relevant installation documents shall be complied with.
Maintenance (To be carried out by trained and duly approved staff)
The user should make sure that the conditions of use and maintenance are complied with (cleaning, replacement of
lamps, replacement with appropriate fuses, tightening of the various components, etc.).
Sammode cannot be held responsible should these instructions not be complied with.
1 Cleaning :
In order to avoid deposits and accumulations of dust on the surface of the luminaires, the user should clean them
regularly. The most appropriate way to clean them is the use a lukewarm, soapy water solution or water with a soft
household cleaning product, using a soft cloth or sponge to remove the dirt and dust. All the surfaces must then be
rinsed with cold water and dried immediately with a soft cloth to avoid water drop traces.
Do not use any abrasive cleaning agents or cleaning products with high alkaline concentration
Never scratch the tubular housing with a scraper, a razor blade or any other sharp tools.
For version II 3G with polycarbonate body: POTENTIAL ELECTROSTATIC CHARGING HAZARD – use only wet cloth or
sponge
2 Lamp replacement:
Lamps should be replaced as soon as they are faulty.
3 Ballast replacement:
The ballasts have a lifetime of 50000h, for a normal use. Beyond that period and at the latest if it proves to be faulty,
the ballast should be replaced.
4 –Repair of the unit:
The repair of the unit cannot be undertaken without SAMMODE’s prior consent in writing