background image

23

ES

MODELO:

MODÈLES SENSOR ULTRA: SUR TABLE                  

SENSOR ULTRA "SU"

SU-310

SU-316

SU-416

SU-420

SU-520

Capacité pompe (m3/h) (1)

10

16

16

20

20

Soudure                     

2 x 2,5 mm

2 x 2,5 mm

2 x 4,3 mm

2 x 4,3 mm

2 x 4,3 mm

Longueur de soudure utile 
(mm)

320

320

420

420

420 + 420

Alimentation électrique

230V/50-60Hz/1

Pompe puissance 

0,37

0,55

0,55

0,75

0,75

Pression vide (max.)

2 hPa (mbar)

2 hPa (mbar)

2 hPa (mbar)

2 hPa (mbar)

2 hPa (mbar)

DIMENSIONS DE LA CHAMBRE
- Largeur (mm)

330

330

430

430

560

- Profondeur (mm)

360

360

415

415

430

- Hauteur (mm)

155

155

180

180

183

DIMENSIONS EXTÉRIEURES
- Largeur (mm)

384

384

484

484

625

- Profondeur (mm)

465

465

529

529

537

- Hauteur (mm)

403

403

448

448

513

Poids net (kg)

34

35

65

70

80

MODELO:

MODÈLES SENSOR ULTRA: SUR PIED                 

SENSOR ULTRA "SU"

SU-604 / 606

SU-604 CC / 

606 CC

SU-806 / 810

SU-806 CC / 

810 CC

SU-806 LL / 

810 LL

SU-6000

SU-6160

Capacité pompe (m3/h) (1)

40 / 63

40 / 63

63 / 100

63 / 100

63 / 100

100

160

Soudure                     

2 x 4,3 mm

2 x 4,3 mm

2 x 4,3 mm

2 x 4,3 mm

2 x 4,3 mm

2 x 4,3 mm

2 x 4,3 mm

Longueur de soudure utile (mm)

413+656                 

465+465

530+848                    

581+581

848+848

660+660

660+660

Alimentation électrique

230-400V/50Hz/3N

Pompe puissance 

1,1 / 1,5

1,1 / 1,5

1,5 / 2,2

1,5 / 2,2

1,5 / 2,2

2,2

4

Pression vide (max.)

0,5 hPa (mbar)

0,5 hPa (mbar)

0,5 hPa (mbar)

0,5 hPa (mbar)

0,5 hPa (mbar)

0,5 hPa (mbar)

0,5 hPa (mbar)

DIMENSIONS DE LA CHAMBRE
- Largeur (mm)

672

672

864

864

864

662

662

- Profondeur (mm)

481

481

603

603

603

656

656

- Hauteur (mm)

200

200

215

215

215

205

205

DIMENSIONS EXTÉRIEURES
- Largeur (mm)

740

740

960

960

960

1640

1640

- Profondeur (mm)

566

566

757

757

757

874

874

- Hauteur (mm)

997

997

998

998

998

1370

1370

Poids net (kg)

145 / 159

145 / 159

232 / 250

232 / 250

232 / 250

360

360

(1) POMPES BUSCH

(1) POMPES BUSCH

Summary of Contents for SU Series

Page 1: ...MANUAL DE INSTRU ES SU E n v a s a d o r a s a l v a c o V a c u u m p a c k a g i n g m a c h i n e s V a k u u m v e r p a c k u n g s m a s c h i n e n M a c h i n e s a e m b a l l e r s o u s v i...

Page 2: ...el ctrico de 1 5 m de largo con recubrimiento termo pl stico ES OBLIGATORIA LA CONEXION CON TIERRA El hilo de toma tierra de la m quina est se alizado Adem s la maquina est provista de un tornillo ext...

Page 3: ...USA VAC O Durante la fase de vac o si se pulsa la tecla la bomba se detiene y se indica en el display el s mbolo manteniendo el vac o Pulsando nuevamente arranca la bomba continuando el proceso de vac...

Page 4: ...ta con los valores autom ticos de Fecha Envasado y VACIO el resto quedan libres para escribir manualmente sobre la etiqueta DESCRIPCION APP PARA SMARTPHONE TABLETA Se carga la aplicaci n en un tel fon...

Page 5: ...a del punto de saturaci n del agua con la relaci n entre la temperatura y la presi n Esto indica aproximadamente el MAXIMO VACIO que se puede hacer para cada temperatura indicada del producto Presi n...

Page 6: ...eso de cocci n e impedir el desarrollo de microorganismos Este proceso se lleva a cabo mediante un abatidor de temperatura Platos refrigerados Se debe rebajar la temperatura de 65 C a 10 C en menos de...

Page 7: ...s earth connection wire is indicated The machine is also fitted with an external screw for the connection to an equipotential earth connection system Three phase machines Prepare a wall mounted mains...

Page 8: ...the display with the vacuum remaining active Press the key once more to start the pump and continue the vacuum process If the lock is activated the packaging program values CANNOT be changed To unloc...

Page 9: ...om the packaging date will be calculated The product 0 is displayed on the display as MANUAL LABEL and only allows label printing with the automatic values Packaging Date and BLANK The rest are free f...

Page 10: ...This table approximately outlines the MAXIMUM VACUUM that can be obtained for each given product temperature Vacuum pressure mbar 1000 100 50 31 67 20 10 6 09 5 2 Vacuum pressure 0 90 1 95 96 87 98 99...

Page 11: ...at low temperatures 65 C to 100 C producing a pasteurising effect This process has many advantages Indeed among others it maintains the nutritional values It safeguards hygiene as there is less handl...

Page 12: ...n de ce qui est indiqu sur le bloc de connexions 2 Modifier si n cessaire les connexions du moteur comme indiqu sur sa plaque bornes 3 R gler si n cessaire le relais thermique en fonction de ce qui es...

Page 13: ...e 99 de Vide l cran affichera sur le cycle la pression finale de vide 99 puis introduira 20 de gaz en affichant 99 20 79 Si la consigne se trouve sur 0 AUCUN gaz ne sera introduit SOUDURE dur e de sce...

Page 14: ...secondes L cran alphanum rique affichera le num ro de version du programme que la plaque lectronique utilise Apr s avoir termin chaque r glage appuyer sur pour teindre la machine puis l allumer nouvea...

Page 15: ...r montage s effectue en rempla ant la barre de soudure par la barre pourvue de fil de coupe et en transf rant la connexion de l un des fils dans le transformateur de soudure sur la tension indiqu e su...

Page 16: ...du r seau lectrique Le niveau de bruit de la machine en marche plac e 1 6 m de hauteur et 1 m de distance est de 75 dB A Bruit de fond 32 dB A Changement d huile Il est n cessaire de contr ler toutes...

Page 17: ...eures de service pr paration l avance des banquets etc Augmentation de la dur e de conservation Le produit doit tre refroidi rapidement au terme de la cuisson afin de stopper la cuisson et d emp cher...

Page 18: ...18 SU 300 SU 420 SU 520 385...

Page 19: ...19 SU 600 SU 800 448...

Page 20: ...20 SU 6000...

Page 21: ...ULTRA SUELO SENSOR ULTRA SU SU 604 606 SU 604 CC 606 CC SU 806 810 SU 806 CC 810 CC SU 806 LL 810 LL SU 6000 SU 6160 Capacidad Bomba m3 h 1 40 63 40 63 63 100 63 100 63 100 100 160 Tipo de Soldadura 2...

Page 22: ...SU SU 604 606 SU 604 CC 606 CC SU 806 810 SU 806 CC 810 CC SU 806 LL 810 LL SU 6000 SU 6160 Vacuum pump m3 h 1 40 63 40 63 63 100 63 100 63 100 100 160 Sealing type 2 x 4 3 mm 2 x 4 3 mm 2 x 4 3 mm 2...

Page 23: ...SU SU 604 606 SU 604 CC 606 CC SU 806 810 SU 806 CC 810 CC SU 806 LL 810 LL SU 6000 SU 6160 Capacit pompe m3 h 1 40 63 40 63 63 100 63 100 63 100 100 160 Soudure 2 x 4 3 mm 2 x 4 3 mm 2 x 4 3 mm 2 x 4...

Page 24: ...ER 0437 1 96 UNE EN ISO 9001 SAMMIC S L Basarte 1 20720 AZKOITIA Spain www sammic com 01 17 2900206 0...

Reviews: