background image

4  |  SAMLEX AMERICA INC.    

 

    

SAMLEX AMERICA INC.  |  5

2nd Step: COnneCt the SOlar MOdule

-  ensure that the solar module is protected from incident light (cover it or wait  

for night).

-  ensure that the solar module does not exceed the maximum permissible  

input current.

-  first connect the M+ solar module connection cable to the correct pole of the left 

pair of terminals on the solar charge controller (with the solar module symbol),  
then connect the M– cable. remove the covering from the solar module.

3rd Step: COnneCt lOadS

-  first connect the l+ load cable to the correct pole of the right pair of terminals on 

the solar charge controller (with the lamp symbol), then connect the l– cable. Insert 
the load fuse or switch on the load.

 

Notes: Connect loads that must not be deactivated by the solar charge controller 
deep discharge protection, e.g. emergency lights or radio connection, directly to the 
battery. loads with a higher current consumption than the device output can be di-
rectly connected to the battery. however, the solar charge controller deep discharge 
protection will no longer intervene. loads connected in this manner must also be 
separately fused.

4th Step: FInal wOrk

fasten all cables with strain relief in the direct vicinity of the solar charge controller 
(clearance of approx. 10 cm).

5. LeD DiSPLAyS

LeD

StAtUS

MeAninG

 INfo leD

Illuminates GreeN

Normal operation.

flashes slowly reD

*

System fault: too high charging current; 
overload/short circuit; overheated.
ToGeTher WITh reD leD: too low bat-
tery voltage.
ToGeTher WITh GreeN leD: too high 
battery voltage.

 battery reD leD

flashes quickly

*

battery empty, low voltage disconnec-
tion pre-warning, loads still oN.

flashes slowly

*

Deep discharge protection active (lVD), 
loads disconnected.

 battery YelloW 
leD

Illuminates

battery weak, loads are oN.

flashes slowly Yel-
loW

*

lVD reconnection set-point has not yet 
been reached, loads still disconnected.

 battery GreeN 
leD

Illuminates

battery good.

flashes quickly 
GreeN

*

battery full, charge regulation active

*

flashing slowly: 0,4hz: 4 times in 10 second, flashing quickly: 3hz: 3 times in 1 second

Summary of Contents for SMC-10

Page 1: ...Solar Charge Controller SMC 10 Please read this manual before installing your Solar Charge Controller Owner s Manual...

Page 2: ...tening Protection 6 Section 8 Maintenance 6 Section 9 Faults Remedies 6 Section 10 Technical Data 7 Section 11 Warranty 8 DETAILED PRODUCT INFORMATION For a complete user manual including specificatio...

Page 3: ...tions for all components of the PV system No energy source other than a solar generator may be connected to the solar charge controller Follow the general and national safety and accident prevention r...

Page 4: ...screws M4 x 40 DIN 7996 4 3 Connection Use a wire size suited to the current rating of the charge controller e g 6mm for 10A for cable length of 10 m An additional external 20A fuse not provided must...

Page 5: ...ut can be di rectly connected to the battery However the solar charge controller deep discharge protection will no longer intervene Loads connected in this manner must also be separately fused 4th ste...

Page 6: ...le strain relief Check that all cable connections are secure Tighten screws if necessary Check corrosion on terminals 9 Faults and remedies No display Check battery polarity and external fuse OR batte...

Page 7: ...6V 22 4V to 23 2V Operating conditions Ambient temperature 25 C to 50 C 13 F to 122 F Fitting and construction Terminal stranded solid wire 3 4 mm2 6 mm2 AWG 12 9 Degree of protection IP 32 Dimension...

Page 8: ...opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no...

Page 9: ...SAMLEX AMERICA INC 9 Notes...

Page 10: ...10 SAMLEX AMERICA INC Notes...

Page 11: ...SAMLEX AMERICA INC 11 Notes...

Page 12: ...0 561 5885 Fax 888 814 5210 Local Numbers Ph 604 525 3836 Fax 604 525 5221 Website www samlexamerica com USA Shipping Warehouse Kent WA Canadian Shipping Warehouse Delta BC Email purchase orders to or...

Page 13: ...R gulateur de Charge Solaire SMC 10 Veuillez consulter ce manuel avant d utiliser votre r gulateur de Charge Solaire Guide d utilisation...

Page 14: ...3 Section 2 S curit 3 Section 3 Fonctions 3 Section 4 Installation 4 Section 5 Affichages DEL 5 SECTION 6 Mise la Terre 6 Section 7 Protection Contre la Foudre 6 Section 8 Entretien 6 Section 9 Erreu...

Page 15: ...ccordez aucune autre source d nergie qu un g n rateur solaire au r gulateur de charge Respectez les consignes g n rales et nationales en mati re de s curit et de la pr vention d accidents Gardez les e...

Page 16: ...olaire passages de c ble vers le bas par moyen des 4 vis t te bomb e M4x40 DIN 7996 4 3 Raccordement Utilisez un c ble d un paisseur adapt e aux caract ristiques actuelles du r gulateur de charge par...

Page 17: ...de mani re identique pour le c ble L Ins rez les fusibles des consommateurs ou branchez les consommateurs Remarques Raccordez les consommateurs qui ne doivent pas tre d connect s par la protection con...

Page 18: ...ection externe contre la foudre ou les surtensions afin d viter toute d faillance Demandez de l assistance technique d un commer ant sp cialis 8 Entretien Le r gulateur de charge n cessite aucun entre...

Page 19: ...le erreur la fois Apr s avoir limin l erreur l appareil va fonctionner de mani re conforme Court circuit au niveau du panneau solaire Inversion de polarit sur le panneau solaire 2 Court circuit la sor...

Page 20: ...ONCTIONNEMENT Temp rature ambiante 25 C 50 C 13 F 122 F INSTALLATION ET CONSTRUCTION Borne de raccordement fil faible diam tre unifiliaire 3 4 mm2 6 mm2 AWG 12 9 Indice de protection IP 32 Dimensions...

Page 21: ...ives de rem dier au d faut par quelqu un d autre que le Garant rendent cette garantie nulle et sans effet Il n existe aucune garantie concernant les d fauts ou dommages caus s par une installation d f...

Page 22: ...10 SAMLEX AMERICA INC Notes...

Page 23: ...SAMLEX AMERICA INC 11 Notes...

Page 24: ...os Sans Frais T l 1 800 561 5885 T l c 1 888 814 5210 Num ros locaux T l 604 525 3836 T l c 604 525 5221 Site internet www samlexamerica com Entrep t USA Kent WA Entrep t Canada Delta BC Adresse email...

Reviews: