Remote off

A switch can be installed between the OFF input and 
the minus (–) to manually disable the BGW output. 
The BGW will shut down immediately when the 
connection is made. The BGW will turn on when  
the connection has been disconnected.

LED

The LED has two functions. One is to indicate the 
BGW’s status. The different stages are explaned in 
the LED STATUS below. The other is to configure/
programme the BGW. This operation is described in 
the section “CONFIGURE/Programming”.

LED STATUS

STAGE EXPLAINED

Led is on.

BGW has enabled 
(switched on) the output.

Two short blinks (then off 
for a longer period).

BGW is disabled because 
the remote off has been 
activated.

One blink (1 second on 
and 1 second off).

Undervoltage or 
overvoltage detected.

Three short blinks (then off 
for a longer period).

BGW has been shut down 
for one minute due to one 
of the following causes: 
Ground loss, temperature 
protection, current 
protection, low output 
voltage.

LED is off.

BGW has been shut down 
due to undervoltage.

CONFIGURE/PROGRAMMING

To enter the configure/programming mode, a 
connection has be made between the CONFIG  
input and the Minus (–). The LED will blink one  
time when the connection has been made for 
approx. 2 seconds. Once this is done, the  
connection has to be disconnected.

The same connection can be made briefly (short) again 
to set the correct position from the programming 
table. The LED will light up as feedback.
At that point, program position #1 is selected.  
The user can briefly (short) make the connection 
again to select programme position #2, etc., etc..

If no connection is made for approx. 4 seconds,  
the LED will display the set state again.  
(Example: programme position #4 is set by a user, 
the LED will blink 4 times)

Two types of settings are available. Positions 1 
through 10 set the undervoltage threshold and reset 
values. Positions 11 and 12 set the overvoltage 
threshold and reset values. These settings must be 
selected individually.

The programmed positions are also retained when 
the battery voltage is disconnected.

PROGRAMMING TABLE

12V

24V

UNDERVOLTAGE (V)

Position

Thres-

hold

Reset

Thres-

hold

Reset

1*

10.5

12

21

24

2

10

11.5

20

23

3

9.5

11.5

19

23

4

11.25

13.25

22.5

26.5

5

11.5

13.8

23

27.6

6

10.5

12.8

21

25.6

7

11.5

12.8

23

25.6

8

11.8

12.8

23.6

25.6

9

12

13

24

26

10

10

13.2

20

26.4

OVERVOLTAGE (V)

Position

Thres-

hold

Reset

Thres-

hold

Reset

11*

16

15.8

32

31.6

12

15.4

15.2

30.8

31.4

* Factory default

Summary of Contents for BGW400

Page 1: ...gh inductive loads always use a suppressor diode from OUT to min Position it as close as possible to the load WIRING DIAGRAM please see last page OPERATION Input voltage protection The input voltage p...

Page 2: ...and the Minus The LED will blink one time when the connection has been made for approx 2 seconds Once this is done the connection has to be disconnected The same connection can be made briefly short...

Page 3: ...inductieve belastingen altijd een blusdiode van OUT naar min Plaats deze zo dicht mogelijk bij de belasting AANSLUITSCHEMA zie laatste bladzijde WERKING Ingangsspanningsbeveiliging De waarden van de...

Page 4: ...en de minus Nadat de verbinding 2 seconden gemaakt is zal de led 1 maal knipperen Zodra dit gebeurd is moet de verbinding verbroken worden Om het juiste positienummer in te stellen moet dezelfde verb...

Page 5: ...00 von der Batterie zum BGW Diesen Anschluss nur f r die BGW verwenden Bei hohen induktiven Lasten ist immer eine L schdiode zwischen OUT und Minus zu verwenden Diese ist so nah wie m glich an der Bel...

Page 6: ...ogrammierungsmodus zu aktivieren muss eine Verbindung zwischen Programmeingang CONFIG und Minus Anschluss hergestellt werden 2 Sekunden nach der Herstellung der Verbindung blinkt die LED einmal auf Gl...

Page 7: ...ion n gative Utilisez cette connexion uniquement pour le BGW En cas de charges d induction lev es toujours monter une diode de suppression de tension transitoire configur e de la borne de sortie OUT v...

Page 8: ...NFIGURER PROGRAMMATION Pour lancer le mode de programmation il faut tablir un contact entre l entr e de CONFIG et la borne n gative La LED 1 se met clignoter d s qu un contact a t tabli pendant 2 seco...

Page 9: ...Para cargas inductivas elevadas siempre debe utilizar un diodo de enfriamiento de salida a menos Posici nelo lo m s cerca posible de la carga ESQUEMA DE CONEXI N Por favor vea la ltima p gina FUNCIONA...

Page 10: ...GURAR PROGRAMACI N Para iniciar el modo de configurar programaci n debe establecerse una conexi n entre la entrada de CONFIG y el min Una vez se haya establecido la conexi n durante 2 segundos el LED...

Page 11: ...mum wire diameter 1 5 mm2 Faston plug 6 3 mm MECHANICAL Mounting hole 4 5 mm Distance between mounting holes centre to centre 1 mm 190 0 mm 71 5 mm Weight 1040 g Dimensions H W L 1 mm 87 5 52 5 206 0...

Page 12: ...s PRODUCT TYPE Battery Guard Waterproof BRAND Samlex Standards to which conformity is declared EN 61000 6 2 2005 EN 61000 6 3 2007 Signed Marcel van Veen Date 20 November 2023 Authority Managing Direc...

Reviews: