Use the Charger
Table 12-1 Normal Functional Check Table
"E.Q." LED (not in Lithium mode)
"STATUS" LED
Status
Red, constantly lit
I/CC phase
Orange, constantly lit
Uo/CV phase
Green, constantly lit
U/battery full phase
Red, constantly lit
Red, constantly lit
I phase, Equalization
is activated
Red, constantly lit
Orange, constantly lit
Uo phase, Equalization
is activated
Red, constantly lit
Green, constantly lit
U phase, Equalization
is activated
Red, constantly lit
Equalization is executed
Red, flashing
I/CC phase, half power
Orange, flashing
Uo/CV phase, half power
Green, flashing
U/battery full phase, half power
Green, double flashing
Power supply mode (not in
Lithium mode)
Red, slowly flashing
Stand-by mode
(RC-600/RC-601D)
13
Trouble Shootings
13.1 The battery voltage would NOT increase after charging
• If possible, measure with a suitable multi-meter during the charging to verify if the voltage
at the battery terminals increases.
• Determine whether the terminals are connected properly to the battery poles. Clean the
battery poles if necessary to ensure better connection.
13.2 The battery is NOT fully charged after a charging time about 20 hours
• Disconnect the power to the charger.
• Remove the battery from the charging terminals and wait for a few minutes.
Then, measure the voltage at the battery terminals with the multi-meter.
Summary of Contents for WSC-1250Li
Page 5: ...5 Figure 6 Cable Setup Figure 5 Making Connections...
Page 6: ...6 Figure 7 Fork Figure 8 Switch...
Page 7: ...7 Figure 9 Temperature Sensor TF 100 Figure 10 Remote Controller RC 600...
Page 8: ...8 Figure 11 Remote Controller RC 600 Dimension mm Figure 12 Remote Controller RC 601D...
Page 9: ...9 Figure 13 Remote Controller RC 601D Dimension mm Figure 14 Making Connections RC 601D...