20
ENG
8
Settings Gel/AGM/Lead-acid
Table 8-2 Switch Configure Equalize Voltage
Switch 3
Equalization voltage
OFF
Same as Uo phase voltage
ON
15.5V/31.0V
Table 8-3 Switch Configure Power/Charger Mode
Switch 4
Operation mode
OFF
Battery charger
ON
Power supply 13.2V/26.4V
Table 8-4 Switch Configure Uo Phase Time Limit
Switch 5
Switch 6
Charging time
ON
OFF
4 hours
OFF
ON
6 hours
ON
ON
8 hours
OFF
OFF
Unlimited
8.2.1 Half power mode setting when using S2
When the switch S2 “HALF POWER” is pushed, the output power will reduce to half of the
chargers' amp rating and the “STATUS” LED will flash. The switch S2 is a kind of no memory
switch. That means "ON/OFF" status cannot be identified from the switch. To enter and exit
the "HALF POWER" mode by turns, please push the switch S2. The "HALF POWER" mode can
be told from flashing "STATUS" LED.
8.2.2 Half power settings via Switch 7
When the Dip Switch 7 is in the ON position, the output power will decrease to half the
maximum current of the charger, and the LED “STATUS” will flash.
Due to the fan speed is adjusted according to the function of the load and the temperature
inside the charger, when "HALF POWER" mode is on, the fan speed will be slowed down and
become silent because of output current reducing to half the charger amp rating.
Note
1. The half power mode can be set only when equalization function is NOT activated or the charger is
NOT in the power supply mode. (see Table 8-6 VOID Setting table for pushing switch on front panel,
Page. 21)
2. Please refer to section 12.1 on page 32 to understand the function of fan speed.
Summary of Contents for WSC-1250Li
Page 5: ...5 Figure 6 Cable Setup Figure 5 Making Connections...
Page 6: ...6 Figure 7 Fork Figure 8 Switch...
Page 7: ...7 Figure 9 Temperature Sensor TF 100 Figure 10 Remote Controller RC 600...
Page 8: ...8 Figure 11 Remote Controller RC 600 Dimension mm Figure 12 Remote Controller RC 601D...
Page 9: ...9 Figure 13 Remote Controller RC 601D Dimension mm Figure 14 Making Connections RC 601D...