Connecting the batteries or other DC loads 

The output has a common Negative(-) terminal and 3 Positive terminals for connection of 3 
banks of batteries. Each Positive connector has it‘s own internal isolating diode which works as
a battery isolator. If more than one bank of batteries is connected, these will be charged at the
sametime (The maximum charging current of 15 A of SEC-1215E / SEC 2415E and 30 A of 
SEC-1230E will be shared among the connected banks of the batteries depending upon their
discharged states) as long as the AC power is available to the charger. In case the AC power fails 
or if there is no output from the charger, the isolating diodes will prevent charging/discharging
among the batteries connected to the banks. 

CAUTION! When a bank consisting of more than one battery in parallel is to be charged,
make sure that their negatives are connected to the common negative terminal of the charger and
their positives are connected to the same positive terminal of the charger. For example, when 
charging a bank consisting of 3 batteries connected in parallel, their 3 negative terminals should be 
connected to the common negative terminal of the charger and all their 3  positive terminals should
be connected to the same (one of the 3) positive terminals of the charger. Alternatively, the negative
terminals of the 3 batteries should first be shorted and then connected to the common negative
terminal of the charger and similarly, the 3 positive terminals of the battery should first be shorted  
and then connected to one of the 3 positive terminal sof the charger.
 

When connecting a single battery or other DC load, it can be connected to the common
negative and any one of the 3 positive terminals.

8

Summary of Contents for SEC - 1215E

Page 1: ...SEC 1215E SEC 1230E SEC 2415E Model No AUTOMATIC BATTERY CHARGER OWNER S MANUAL Please read this manual before operating your charger...

Page 2: ...IMPORTANT SAFETY PRECAUTIONS 2 DESCRIPTION AND FEATURES 3 CHARGING STAGES 4 PROTECTIONS 5 INSTALLATION 6 CHARGER OPERATION 7 8 9 10 TROUBLESHOOTING 11 12 INTERNAL FUSE RATINGS 12 SPECIFICATIONS 13 WAR...

Page 3: ...e compartment as batteries ChargerRelated r Do not operate the charger in a closed in area or restrict ventilation in any way Install in a well ventilated cool dry place r The charger must not be oper...

Page 4: ...rolled cooling fan SEC 1230E SEC 2415E r Protectionsagainst short circuit overcurrent reverse battery connection and over temperature over temperature for SEC 1230E and SEC 2415E r Can be used as a po...

Page 5: ...e threshold of battery gassing termed boost or absorption voltage the charger automatically switches over to Stage 2 Boost or Absorption Stage The value of this voltage depends upon the type of batter...

Page 6: ...draw a higher current than these limits the output voltage of the unit will start to drop The unit will automatically recover when the overload condition is removed Reverse Battery Connection Cut Off...

Page 7: ...1230E 6mm CAUTION For firm connection when using stranded cable crimp solder pin style terminal on the charger end of the DC cables used for connecting to the battery other DC loads Cables To avoid p...

Page 8: ...ng Always change the Dip Switch setting when the charger is off i e after disconnecting the charger from the AC input power NOTE The voltages are for a temperature of 80 Degrees F DIPSWITCH SETTINGS S...

Page 9: ...nsisting of more than one battery in parallel is to be charged make sure that their negatives are connected to the common negative terminal of the charger and their positives are connected to the same...

Page 10: ...frame or engine block which is away from battery Do not connect to carburetor fuel lines or sheet metal body parts 6 For a positive grounded vehicle connect the negative black DC cable from the charge...

Page 11: ...current drawn by the DC load is below the maximum current rating of the charger Switch on the charger and then the DC load In a DC UPS Un interruptible Power Supply the charger simultaneously powers t...

Page 12: ...S GETTING OVER CHARGED OR BOILS The charger is also feeding other DC load s in parallel with the battery The Dip Switch is not selected for Battery with Load Change Dip Switch setting to Battery under...

Page 13: ...y reach up to 10 times their normal operating currents Ensure that the starting in rush current or the maximum operating current of the load is lower than the current limit value of the charger INTERN...

Page 14: ...1 13 8 VDC 13 8 VDC 27 6 VDC Output Amps 15 A 30 A 15 A Operating Temp Range 0 40 C 0 40 C 0 40 C Weight 2 35 kgs 3 1 kgs 3 1 kgs Housing Dimensions LXWXH mms 215x213x80 273x213x80 273x213x80 Protect...

Page 15: ...rmed only by the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty instal...

Page 16: ...www samlex com www samlex solar com...

Reviews: