background image

GRIZZL  E

EV Charger

User Manual
& Installation Guide

Summary of Contents for Grizzl-E Classic

Page 1: ...GRIZZL E EV Charger User Manual Installation Guide...

Page 2: ...nual Revision 2 5 Model Numbers Grizzl E Classic GR1 6 18 R GR1 6 24 R GR1 6 24 P GR1 14 18 R GR1 14 24 R GR1 14 24 P Grizzl E Avalanche Edition GR1 14 24 AB GR1 6 24 AB GR1 14 24 AW Grizzl E Special...

Page 3: ...the Grizzl E Electric Vehicle Supply Equipment EVSE Before installing or using the EVSE read this document including any WARNING and CAUTION symbols The Symbols Used Have the Following Meanings Warni...

Page 4: ...nsion cord or electrical adapter Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a licensed electrician if you are in doubt as to whether the...

Page 5: ...edicated Circuit as follows 50A Circuit Rating To support 40A 9 6kW Maximum Charging Station Output 40A Circuit Rating To support 32A 7 68kW Maximum Charging Station Output 30A Circuit Rating To suppo...

Page 6: ...or use with 20A Circuit Rating Charge Cable Length 18 ft 5 5m for GR1 6 18 XX and GR1 14 18 XX 24 ft 7 2m for GR1 6 24 XX and GR1 14 24 XX Electrical Circuit Input Power Requirements Dedicated 208VAC...

Page 7: ...Tools Parts Required for Installation 14 4 2 Install the Charging Station 15 5 Wiring Connection 18 5 1 Optional Hardwire Connection 18 5 2 Replace Output Cable 20 6 EasyEvPlug Holster and Cable Manag...

Page 8: ...8 1 Introduction Unpacking 1 1 Your Charger Charger Components 1 Input Cable NEMA 14 50P or NEMA 6 50 2 Output Cable J1772 Connector 3 Latch Release Button 4 Indicator Light 1 4 2 3...

Page 9: ...9 Mounting Bracket x1 Security Pin x1 Front Plate Screw x4 Back Plate Screws x2 Holster x1 Holster Anchor x4 Holster Screws x4 1 2 Package Contents Mounting Kit EasyEvPlug Holster...

Page 10: ...tory Setting a DEDICATED CIRCUIT rated for 40A 208VAC Single Phase or 240VAC Split Phase 50 60 Hz 24A Maximum Output Setting Default Factory Setting a DEDICATED CIRCUIT rated for 30A 208VAC Single Pha...

Page 11: ...ut Setting is 40A 9 6 kW for use with a 50A Circuit Rating The Circuit must be a DEDICATED CIRCUIT 208VAC Single Phase or 240VAC Split Phase Requirements govern that only 80 of the circuit rated load...

Page 12: ...ition switch on the main circuit board located directly to the left of the LED DOWN UP UP UP WARNING Do not touch live electrical parts Disconnect the power supply to the charging station before adjus...

Page 13: ...m Current Output Factory Default Setting UP UP UP DOWN 32A Maximum Current Output UP DOWN UP DOWN 24A Maximum Current Output UP UP DOWN DOWN 16A Maximum Current Output UP DOWN DOWN DOWN 5 Once the DIP...

Page 14: ...n 255 x 48 x 36 mm 14 8 1 1 4 8 5 16 x 1 2 PH3 5 32 Included with Product Included with Product Included with Product Included with Product Included with Product Included with Product Commercially Ava...

Page 15: ...e mounting bracket by pushing down on the notch Front Piece Back Piece 2 Attach the front piece of the mounting bracket to the back of the charging station using the Front Plate screws Ensure the top...

Page 16: ...ew Recommendations For finished walls supported by wood studs use 14 or M6 tapping screws Included For masonry walls use M6 mechanical screws Commercially available Use following torque force Screw To...

Page 17: ...the front piece of the mounting bracket to the back piece of the mounting bracket 5 Secure the charger in place by inserting either the security pin or the outdoor security lock into the mounting brac...

Page 18: ...the 4 screws at each corner of the charging station 4 Loosen the plastic cable gland beneath the charger 5 Loosen strain relief clamp on inside of charger Use a screwdriver or other tool to break and...

Page 19: ...protection in accordance with the National Electrical Code ANSI NFPA 70 and the Canadian Electrical Code Part I C22 1 8 Once the input wiring and conduit are connected reassemble the charging station...

Page 20: ...l wires through the Cable Gland and into the enclosure Feed the Input Cable through the enclosure such that of the black rubber jacket is exposed 7 Place metal strain relief clamp through terminal wir...

Page 21: ...al angle for less wall clearance Integrated cable management holds up to 25 feet of cable The EasyEvPlug holster can be installed at any location near the charging station 1 Hold back of holster again...

Page 22: ...o current consumed by the car Buzzer beeps Red Flashing Fault 7 2 LED Fault Indicator The number of red flashes indicates the type of fault LED Indicator of Flashes Error Description Red Flashing 1 Lo...

Page 23: ...he error condition is not cleared the charger will continue to display a RED error light If the error condition occurs within 5 seconds of the start of a charging session a permanent fault will trigge...

Page 24: ...nsure the connector is fully seated locked in place Once complete the charging session will begin 8 2 Stop Charging 1 Press down on the latch release button Ensure latch release button is fully compre...

Page 25: ...the enclosure cannot be guaranteed if the charger is mounted upside down Ensure the charging connector is put back in the holster after charging to avoid damage Ensure the power cable is stored on the...

Page 26: ...not include normal tear and wear Plugs that have been exposed to snow or water for a prolonged period of time are not covered by this warranty The waterproof rating of the enclosure cannot be guarante...