B - 2023/06
5 The
Inotransfer
equipment must be maintained regularly in accordance with the indications and instructions
given by
Sames
. Repairs must be carried out in strict accordance with these instructions.
6 It is imperative to ensure that any conductive or semi-conductive parts that are less than 2.5 m away from any
projector are properly grounded. Otherwise, it could accumulate electrical charges capable of causing sparks.
7 Earthing is required of all conductive enclosures of electrical equipment and all conduc-tive components in
potentially explosive atmospheres by conductive connection to the earth terminal.
8 For the same reasons, it will be necessary, in the coating area, to have an antistatic floor such as bare concrete,
metal grating, etc...
9 Ensure that the pneumatic pressure inside is completely exhausted before adjusting or servicing pressurized
systems or parts.
10 Disconnect, lock out and switch off electrical equipment before servicing electrical equipment.
11 Switch off all electrical or electrostatic equipment immediately, even if you are exposed to a slight electric
shock. Do not restart the equipment until the problem has been identified and resolved.
1.5. Important recommendations
1.5.1. Ambient temperature
The
Inotransfer
equipment is designed to normally operate at an ambient temperature comprised between 0°C and
+ 40°C. The storage temperature must never 60°C.
1.5.2. Sound level
1.5.2.1.
Inotransfer
during the pumping phase
The sound pressure level generated is equal to 89.7 dBA under the specified operating conditions.
Conditions of measurement:
The equipment was put into operation at maximum characteristics, the
measurements were carried out at different positions at 1 m from the cart in the Powder laboratory at the
Sames
site in Meylan, France.
Method of measurement:
The accoustic pressure level, continuous, equivalent, weighted 89.7 dBA is given in LEQ
value, measured for observation periods of at least 30 seconds.
1.5.2.2.
Inotransfer
during the cleaning phase
The sound pressure level generated is equal to 72 dBA under the specified operating conditions.
Conditions of measurement:
The equipment was put into operation at maximum characteristics, the
measurements were carried out at different positions at 1 m from the cart in the Powder laboratory at the
Sames
site in Meylan, France.
Method of measurement:
The accoustic pressure level, continuous, equivalent, weighted 72 dBA is given in LEQ
value, measured for observation periods of at least 30 seconds.