3.3. Flow performance
The powder flow rate measurements are given as an indication because they depend on several parameters, suction
distance, output distance, density of the powder put in motion, height difference, container, etc...
Flow rate (4 m suction, 6 m output, 1m height difference) 5.5 Kg/min.
3.4. Operating principle
Pumping phase
For optimum efficiency, the
Inotransfer
pump should be installed as close as possible to the powder container. The
container must be either vibrated to facilitate the flow of the powder and avoid any cratering, or fluidized. The pump
must be installed vertically and the circulation of the powder must be from top to bottom (
).
After switching on with switch (
B
), select the operating mode (blowing/pumping) with switch (
C
). Switch (
A
) is used
to enable or disable the cycle.
Flow performance
Use example 1
Use example 2
Maximum value
Suction hose length
4
6
6
Length of discharge hose (m)
6
25
25
Operating cycle (s)
0.5
0.5
2
Blowing pressure (bar)
0.8
2
3.5
Flow rate (Kg/min)
5.5
5
5.5
Sleeve control pressure (bar)
4
4
5
A
B
C