5. Start up
5.1. Specific tool
None.
5.2. Installation
The
Inocart NDT
or
HF
carts are delivered assembled.
•
Step 1
: Connect the ground cable of the cart to a
conductive and earthed part of the spray booth; the
ground potential must be identical to that of the part
to be powdered.
•
Step 1
:: Attach the tank support to the base of the
cart using the 4 screws 8 x 25 provided.
•
Step 2
: Connect the air supply and ground wire to
the tank:
Gun powder supply hose (
1
)
Green/yellow wire: ground (
2
).
Hose 4/6: dilution air for fluidization (
3
)
Hose 6/8: injection air (
4
).
•
Step 3
: Connect the 5 m earthing cable to an
electrically earthed part of the application booth.
•
Step 4
: Connect the Inobox's power supply plug.
•
Step 5
: Connect the electrode blowing hose on
the
Inobox
module side and on the gun side.
The cart is ready to start the powder application.
2
3
4
1