SAMES KREMLIN
- 3 -
N° : 578.224.110-UK-1710
Index
Instructions
Description
Part number
A 1
PTFE grease
PTFE grease (10 ml / 0.0026 US gal)
560.440.101
C 2
Low strength
- Anaerobic Adhesive
Loctite 222 (50 ml / 0.013 US gal)
554.180.010
S 1
Torque screwing :
18 Nm / 13.276 Ft/Lbs
S 2
Torque screwing :
10 Nm / 7.376 Ft/Lbs
S 3
Torque screwing :
5 Nm / 3.688 Ft/Lbs
PROJECTOR (IND. 1 + 7 + 11) & VORTEX (IND. 18) REPLACEMENT
Unscrew the aircap assembly (1), then remove the aircap ring (2), the aircap only (4), the stop ring
(5) and the ring seal (6).
Trigger the gun (36) then unscrew the nozzle assembly (7) with the wrench provided with the gun.
Remove the distribution ring (8) and the nozzle seal (10).
Remove the vortex (18) and the distribution ring (19).
For the guns, model FPRO P LP and CONV : unscrew the needle stop (22), then remove the needle
spring (20) and the needle (11) by the rear part of the gun.
For the guns, model FPRO P LOCK LP and LOCK CONV : unscrew the needle stop sleeve (17),
then remove the needle (11) by the rear part of the gun.
Check parts’ conditions. Change them if necessary.
Lubricate the needle (11) and the needle spring (20) with grease.
For the guns, model FPRO P LP and CONV : reinstall them as well as the needle stop (22).
For the guns, model FPRO P LOCK LP and LOCK CONV : reinstall them as well as the needle stop
sleeve (17) - screwing torque : 5 Nm / 3.688 Ft/Lbs.
Reinstall the distribution ring (19) and the vortex (18).
Reinstall the new nozzle assembly (7). Tighten it by means of the wrench - screwing torque : 18 Nm
/ 13.276 Ft/Lbs.
Reinstall the new aircap assembly (1).