SAMES KREMLIN
- 2 -
N° : 578.026.110-UK-1708
TROUBLE
CAUSE
SOLUTION
No fluid out of the gun
Clogged nozzle
Cut the pressure on the pump.
Depressurize the hoses.
Remove and clean the nozzle with
solvent by means of the brush.
Check the seal condition.
Pattern width narrows during
reversing phase of pump
Air trapped in the fluid circuit
Check connections and suction
hose quality.
Viscosity too high
Reduce viscosity.
Aircap becomes dirty frequently
Too much atomizing air
Reduce air pressure.
Fluid seeping from the air holes of
the aircap
Defective tip seal
Replace it.
Tip loose
Tighten it.
Fluid leak at the packing
Packing is worn
Tighten up the packing holder
without blocking the needle.
If there is still a leak, replace the
packing and the needle
.
Fluid leak at the front part of the
gun, trigger released
Impurities in the paint
Trigger the gun 3 or 4 times.
Needle worn or/and nozzle worn
Replace needle and nozzle.
Air leak at the valve
Valve worn
Change the valve.
Permanent air leak at the gun
aircap when the trigger is released
Friction on the needle
Remove the trigger and check the
needle.
Valve worn
Replace the valve.