SAMES KREMLIN
Page 5
Manual : 573.008.212
INSTALLATION DIAGRAM WITH CIRCULATING
1
B
A
Z1
Z2
Z2
1m
1m
6
5
5
5
3
3
2
2
A -
B -
1 -
2 -
3 -
5 -
6 -
Explosive area
area 1 (Z1)
or area 2 (Z2) :
spraybooth
Non explosive
area
Pump
Gun
Pressure regulator
(spring or air
operated)
Conductive hose
Back pressure
regulator
The 1 m / 39.37" distance indicated in these diagrams is given for information
purposes only and hold harmless to SAMES KREMLIN. The user is responsible for the
extraction and conditioning of the painting area where the equipment is used, for
working conditions conditions (refer to EN 60079-10 standard). The 1 m / 39.37"
distance may be modified if trials carried out by the user deem this necessary.
(Nota : diagrams represented with Airmix® regulators)
NOTA :
To ensure a larger lifetime of your equipment and to obtain the best flow
rate possible, you must mount the regulator in vertical position.
5. START
UP
Start up the pump (Refer to pump instruction manual).
Tighten the screw located on the upper part of the spring operated regulator or turn the regulator of the air
operated assembly.
Start up the gun (Refer to gun instruction manual).
Adjust the fluid regulator to obtain the required pressure and fluid flow.
Nota : Refer to the regulator features to comply with the inlet and outlet pressures (refer to the
enclosed document).
6. MAINTENANCE
Keep the pressure regulator clean to ensure its proper working.
When flushing the pump, make the solvent circulate in circuit to clean all the elements (pump, hoses,
regulator, gun).