Safety Instructions 

 

Please  observe  the  national  safety  regulations  and  regulations  for  prevention  of 
accidents, as well as to the safety instructions given below in this User Manual! 
 

Attention! 
Repairs may only be carried out by using original parts from the man-
ufacturer. Repairs may only be carried out in  accordance with the na-
tionally applied regulations and exclusively by the manufacturer. 

 

Attention! 
Prior to installation, take external sources of heat or cold into account! 
The  temperature ranges prescribed for storage,  transport and operat-
ing must be adhered to! 

 
 

Installation 

 
For  commissioning  and  operating  the  camera,  the  relevant  national  regulations,  as  well 
as the generally accepted rules of technology shall prevail. Before mounting the camera, 
thoroughly check it for any transport damage, especially on the housing and cable. Instal-
lation,  electrical connection and the first  start must  only be carried out  by qualified spe-
cialists. 
 

Work preparation: 

 

Attention! 
Prepare  your  work  carefully  and  in  accordance  with  the  relevant 
regulations. 

 
To ensure the best  image quality delivered by the network camera,  plan the installation 
site carefully (consider light conditions, object distance or size, angle and minimum object 
distance to the focus).  
 

  Use appropriate tools and aids. 

  When working, ensure a safe stand. 

  Make sure that any static charge is avoided. 

 
The  RoughCam

®

  IPP1275  consists  of  a  robust  sensor  housing  (T10)  and  a  Main  Unit 

P12  MkII  for  safe  areas.  The  sensor  unit  is  equipped  with  a  flexible  cable  (5  to  25  m). 
Mount the sensor unit according to the desired field of view. Install the main unit so that a 
good accessibility is provided, in order to facilitate electrical connection.  
 

Summary of Contents for RoughCam IPP1275

Page 1: ...RoughCam IPP1275 User Manual...

Page 2: ...vice terminal box and fuses 11 5 2 1 Direct routing 11 5 2 2 Plug assignments RJ12 of the sensor unit 11 5 2 3 Tests prior to switching on voltage 12 6 Working inside the housing 13 6 1 Preparation fo...

Page 3: ...RoughCam IPP1275 T10 VA0 1 K1 BOR N N xxx N P 11 Table 6 2 Pin assignment of the RJ12 plug SKD04 T flex 12 Figure 6 1 Opening the RoughCam IPP1275 Fig similar 13 Figure 6 2 Structure of the main unit...

Page 4: ...well as outdoor applications It is extreme ly robust and therefore perfect for even the roughest industrial conditions The stainless steel housing allows additional alloys a powder coating or coats of...

Page 5: ...l 1 4404 with small diameter VA2 48mm VA0 1 K1 BOR T11 VA0 1 housing with minimum body length L R 127mm VA0 1 K1 BOR K1 cable gland flange VA0 1 K1 BOR Borosilicate sight glass DIN7080 standard for vi...

Page 6: ...module Jacket colour Green GN similar to RAL 6018 Outside diameter 8 7 0 3 mm Bending radius 8 x Da when installed and 4 x Da after installation Temperature 25 C 80 C during installation 60 C 80 C fi...

Page 7: ...Transport storage temperature 0 C 50 C Ambient temperature EX 20 C 50 C Other technical data see https www samcon eu en products roughcam roughcam ipp1275 Table 2 2 Other technical data Sensor Unit Ex...

Page 8: ...nology shall prevail Before mounting the camera thoroughly check it for any transport damage especially on the housing and cable Instal lation electrical connection and the first start must only be ca...

Page 9: ...n walls Material stainless steel 1 4404 Weight 0 68 kg Dimensions 80 x 100 x 205 mm Pole adapter PMB POLE MOUNT EXCAM VA1 x Pole apter for VA wall mount Material stainless steel 1 4404 Suitable for po...

Page 10: ...ient The user is NOT authorised to do electrical connection procedures inside the pressure resistant enclosure 5 1 Potential equalization Figure 5 1 RoughCam IPP1275 Potential equalization Potential e...

Page 11: ...over Ethernet PoE The plug Fig 5 2 is to be connected to the PoE outlet of the Main Unit P12 MkII without pressure tight casing It is suggested connecting the Sensor Unit with the Main Unit prior to p...

Page 12: ...hat the cable shield is grounded on side of the terminal block The maximum cable length between camera and terminal box is 25 m 5 2 3 Tests prior to switching on voltage Attention Prior to starting th...

Page 13: ...E 243 chemical basis is dimethacrylate ester applied to prevent the bolted con nection from unintentional loosening because of impacts and vibrations and to seal them tightly It is not permitted for t...

Page 14: ...d or its state is uncontrollable the reset should be performed manually To do so proceed as follows 1 Disconnect the camera installation module Axis P1275 from the power supply 2 Press and hold the co...

Page 15: ...ing Dismantled screw locks spring washers DIN 127A must be used again The GYLON gasket must be used in undamaged condition according to the flange hole pattern and placed between the flange and the hu...

Page 16: ...ase the applicable settings have to be carried out inside the menu System Options Advanced Plain Config User root Password root 7 1 Browser Support A list of the currently supported web browsers opera...

Page 17: ...ices in po tentially explosive atmospheres must be adhered to The required maintenance intervals are specific to the individual devices The operating company has to determine these intervals depending...

Page 18: ...ings 3D models certificates and other information are available in the download area of the product page on our website https www samcon eu en products roughcam roughcam ipp1275 If you wish additional...

Page 19: ...Doc ID 210212 PT10BA ES RoughCam IPP1275_en_rev 00 docx Page 19 of 20 12 Notes...

Page 20: ...Schillerstrasse 17 35102 Lohra Altenvers Germany www samcon eu info samcon eu Phone 49 6426 9231 0 fax 31...

Reviews: