Doc.-ID: 210212-PT10BA-ES-RoughCam IPP1275_en_rev.00.docx, Page 5 of 20
2
Technical data
2.1
Illustration of the model key
1)
Productname
2)
Type
3)
Housing-
combination
4)
Temp.-
range
5)
Cable
length [m]
6)
Cable
termin.
RoughCam
IPP1275
T10-
VA0.1.K1.BOR-
N.N-
005.N-
P
Table 2-1 Model key
Explanations:
1)
RoughCam IP
P1275 =
Functional camera description of the RoughCam Series (technical data/
specification of the individual camera module)
2)
T
10
=
SAMCON Production- Type 10 cameras for safe areas
3)
VA0
.1.K1.BOR =
T11 housing (stainless steel 1.4404) with small diameter
Ø
VA2
=48mm)
VA0.
1
.K1.BOR =
T11 VA0.1 housing with minimum body length (L
.R
= 127mm)
VA0.1.
K1
.BOR =
K1 cable gland flange
VA0.1.K1.
BOR
=
Borosilicate sight glass DIN7080 (standard, for video cameras within visible
spectral range:
λ = 350…2000 [nm] and photografical infrared range (NIR),
not suitable for thermographic applications (MIR/ FIR)
4)
N.
N
=
Normal ambient temperature range (T
amb
> -20°C)
N.
N
=
No high temperature battery installed (T
amb
< +50°C)
5)
005.
N =
Length of the connection line in meter at delivery; 5m is the
standard cable length, max. cable length is: 003
…25 [m]
005.
N
=
Non armoured cable
6)
P
=
Plug- termination (
standard
)
CAT6, RJ-12 network plug (heavy duty), AWG 26-22,
contact assignment acc. To specification EIA/TIA-568
B