Faults and fault rectification
If faults should occur, check them using the following table:
Fault
Possible cause
Remedy
The green indi
cator light does
not illuminate
when switched
on.
Main switch before appliance
not turned on.
Turn on main switch.
There is no power supply at
all.
Inform the power supply company.
Mains fuse on site has
tripped.
Possible faults on the appliance must
be checked by an authorised Customer
Service agent.
Reset the circuit breaker.
The appliance
does not heat up
and both yellow
indicator lights
are off.
For example, the appliance
has been overheated due to
heating when dry.
The temperature limiter has
switched off the heating ele
ment.
Switch off the unit.
Wait until the appliance has cooled
down.
Pour water into the tank.
Reactivate the temperature limiter with
the reset button.
Switch on the appliance.
If the problem occurs again, have the
appliance checked by authorized cus
tomer service.
Screw cap over reset
button for temperature limi
ter
If the fault cannot be rectified:
‒ switch off the appliance and disconnect from the mains,
‒ do not open the housing,