22
Materials: M1
Mean time: 0 time
Upper limit alarm: 999 (HLD)
Lower limit alarm: 150 (HLD)
Memory: off
Display view: normal
7.
Changing impact body
This tester has a very unique feature, which impact device can convert between D and DL
simply by changing impact body. This two-in-one probe is equivalent to two individual
probes. With this optional accessory, you can take measurement at very narrow surface
such as slot bottom, gear tooth that probe D cannot match.
Please refer to the following steps to change impact body.
Unscrew the support ring from the tester and let the impact body D out.
Insert the impact body DL into probe and screw the guide tube onto the probe.
Set impact device to DL from the tester’s menu. Please refer to 0
Figure 7-1 Hardness tester with DL probe
8.
Take Measuring
8.1.
Loading Spring
8.1.1.
Hold the main body (the tester) with left hand while right hand is holding loading tube.
As figure 8-1
Figure 8-1